Event Notification Report for March 24, 2003




                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/21/2003 - 03/24/2003

                              ** EVENT NUMBERS **

39686  39687  39688  39690  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39686       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK                 REGION:  1  |NOTIFICATION DATE: 03/21/2003|
|    UNIT:  [1] [] []                 STATE:  NH |NOTIFICATION TIME: 21:21[EST]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        03/21/2003|
+------------------------------------------------+EVENT TIME:        20:53[EST]|
| NRC NOTIFIED BY:  MARK McCARTHY                |LAST UPDATE DATE:  03/22/2003|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          UNUSUAL EVENT         |PETE ESELGROTH       R1      |
|10 CFR SECTION:                                 |STUART RICHARDS      NRR     |
|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |NADER MAMISH         IRO     |
|                                                |WATCH OFFICER        FEMA    |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO POTENTIAL INTRUDER INSIDE THE PA               |
|                                                                              |
| The licensee provided the following information during their initial call:   |
|                                                                              |
| "We declared a UE (Unusual Event) [at 2053 EST] based on 18A.  Security      |
| declared code Red.  We have an intruder in the PA (Protected Area).  We have |
| no indications of off normal plant conditions and we have no specific threat |
| indicated."                                                                  |
|                                                                              |
| The licensee initially reported that their CAS (Central Alarm Station)       |
| received an alarm from the security fence around the PA.  Some security      |
| force members reported seeing some sort of object come over the fence        |
| simultaneous with the alarm.  Site security immediately responded to the     |
| situation, along with the Seabrook Emergency Response Team (SERT), and the   |
| FBI.                                                                         |
|                                                                              |
| Region I developed a timeline for this event, contact the HOO for details.   |
|                                                                              |
| An ongoing conference bridge was established with NSIR management (Holonich, |
| Zimmerman), headquarters and regional IAT members (Warren, Smith, Whitney),  |
| Region I management (Miller, Wiggins, Blough, McDermott, Frechette), the NRC |
| Resident Inspector (Dentel), and the FBI.                                    |
|                                                                              |
| The NRC went to Monitoring Mode for this event at 2230 EST on 3/22/03.       |
|                                                                              |
| *** UPDATE AT 0720 EST ON 3/22/03 BY ERIC THOMAS ***                         |
|                                                                              |
| The FBI is conducting interviews with 4 site security personnel.  The FBI    |
| has completed two of four interviews with security personnel.  One, who was  |
| in the CAS, says he saw a square-looking object cross his screen that        |
| monitors the protected area boundary.  The second interviewee was patrolling |
| outside the protected area in his vehicle and saw a large bird (probably a   |
| wild turkey) with approximately a four-foot wing span fly across the road in |
| front of him.  This coincides with the location and time at which the CAS    |
| operator saw the image on his screen.                                        |
|                                                                              |
| The licensee is planning to perform walkdowns of all vital systems, and the  |
| SERT teams are performing additional sweeps of the protected area this       |
| morning.  Additionally, licensee personnel in the Seabrook TSC are updating  |
| Region I NRC personnel on the situation every 30 minutes.                    |
|                                                                              |
| *** UPDATE AT 1030 EST ON 3/22/03 BY ERIC THOMAS ***                         |
|                                                                              |
| Security personnel completed second sweep of the protected area at 0955 with |
| negative results.  Interviews with 4 security personnel by the FBI revealed  |
| the following likely scenario:                                               |
|                                                                              |
| - Approximately 2030 on 3/21/03 - PA fence alarm coincides with CAS security |
| officer seeing a  dark mass  coming over the fence on his monitor.  CAS      |
| personnel then saw this featureless mass disappear behind a building inside  |
| the PA.                                                                      |
|                                                                              |
| - Approximately 2100 - CAS security officer notices dark mass on the monitor |
| fly from a building downward over the PA security fence.  Shortly            |
| thereafter, a security officer on patrol outside the PA sees a wild turkey   |
| with approx. 4-foot wing span fly across the road about 20 feet in front of  |
| his vehicle.                                                                 |
|                                                                              |
| Searches of the fence line in the area of the intrusion revealed no          |
| footprints or damage to the fence.  Conclusion by site operations and        |
| security personnel, as well as FBI, is that the fence alarm was caused by    |
| intrusion of some sort of wild animal, possibly a turkey, and that there was |
| no human intrusion onto the site.                                            |
|                                                                              |
| *** UPDATE AT 1102 EST ON 3/22/03 BY LICENSEE TO ERIC THOMAS ***             |
|                                                                              |
| The licensee terminated the Unusual Event at 1052 EST on 3/22/03.            |
|                                                                              |
| *** UPDATE AT 1235 EST ON 3/22/03 BY ERIC THOMAS ***                         |
|                                                                              |
| The NRC exited Monitoring Mode at 1205 EST.                                  |
|                                                                              |
| A Commissioners' Assistants' brief was held at 1230 EST.  See HOO log for    |
| additional details.                                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39687       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WOLF CREEK               REGION:  4  |NOTIFICATION DATE: 03/22/2003|
|    UNIT:  [1] [] []                 STATE:  KS |NOTIFICATION TIME: 08:30[EST]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        03/21/2003|
+------------------------------------------------+EVENT TIME:        22:07[CST]|
| NRC NOTIFIED BY:  DAVE DEES                    |LAST UPDATE DATE:  03/23/2003|
|  HQ OPS OFFICER:  ERIC THOMAS                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CLAUDE JOHNSON       R4      |
|10 CFR SECTION:                                 |                             |
|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF COMMUNICATIONS WITH SAFETY PARAMETERS DISPLAY                        |
|                                                                              |
| "On 3/21/2003 at 22:07, the Wolf Creek Generating Station experienced an     |
| unexpected loss of the Nuclear Plant Information System (NPIS) Computer.     |
| This computer supplies data for the Safety Parameter Display System (SPDS).  |
| Trouble shooting efforts have been unsuccessful, thus far, in restoring the  |
| system.  Because SPDS has been lost for longer than a short period of time,  |
| Wolf Creek Nuclear Operating Corporation is making this notification         |
| pursuant to 10 CFR50.72(b)(3)(xiii).  There is no other loss of emergency    |
| assessment capability concurrent with this on going loss of the SPDS. Plant  |
| personnel entered the applicable Off Normal procedures and are taking local  |
| readings of equipment normally monitored by the NPIS Computer."              |
|                                                                              |
| The Licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| *** UPDATE ON 3/23/03 AT 1645 CST FROM DAVE DEES TO ARLON COSTA ***          |
|                                                                              |
| "At 1320 CST 3/23/2003 the NPIS Computer was returned to service and         |
| declared operable. The return of the NPIS Computer to an operable condition  |
| restored the SPDS assessment capability function."                           |
|                                                                              |
| The Licensee will notify  the NRC Resident Inspector.                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39688       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 03/22/2003|
|    UNIT:  [1] [2] []                STATE:  PA |NOTIFICATION TIME: 17:40[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/22/2003|
+------------------------------------------------+EVENT TIME:        16:45[EST]|
| NRC NOTIFIED BY:  ROBERT BOESCH                |LAST UPDATE DATE:  03/22/2003|
|  HQ OPS OFFICER:  ARLON COSTA                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |PETE ESELGROTH       R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| NOTIFICATION TO PEMA OF CONTRACTOR TRANSPORTED OFFSITE FOR TREATMENT         |
|                                                                              |
| "On 3/22/03 at 1645 the Main Control Room was notified of an individual      |
| (Contractor) experiencing symptoms of a Heart Condition.  An ambulance was   |
| dispatched to the site. The individual was in an office space at the time of |
| the occurrence and was not contaminated.  Site EMTs responded and the        |
| individual was found to be conscious and stable.  The Pennsylvania Emergency |
| Management Agency [PEMA] was notified at 1655.  The individual was           |
| transported to a local hospital for treatment.  The ambulance left site at   |
| 1725.  Due to notification to another government agency, this event is       |
| reportable under 10CFR50.72(b)(2)(xi)."                                      |
|                                                                              |
| The Licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39690       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DIABLO CANYON            REGION:  4  |NOTIFICATION DATE: 03/22/2003|
|    UNIT:  [1] [] []                 STATE:  CA |NOTIFICATION TIME: 20:20[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/22/2003|
+------------------------------------------------+EVENT TIME:        16:33[PST]|
| NRC NOTIFIED BY:  MICHAEL KENNEDY              |LAST UPDATE DATE:  03/22/2003|
|  HQ OPS OFFICER:  ARLON COSTA                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CLAUDE JOHNSON       R4      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BABY SEA OTTER TRAPPED AT PLANT INLET                                        |
|                                                                              |
| "A baby Sea Otter, an endangered animal is trapped at the Auxiliary Salt     |
| water pump inlet between the bar racks and screens.  The mother Otter is     |
| outside of the bar racks.  We have contacted a diver to assist the [baby]    |
| Otter to safety.  We have also secured the screen such that it will not      |
| start until we have moved the [baby] Otter to safety. This is being reported |
| as an endangered sea animal taken on-site, alive, and state agencies may be  |
| notified.   We are coordinating the rescue with the Marine Mammal Rescue     |
| Center."                                                                     |
|                                                                              |
| The Licensee will notify the NRC Resident Inspector, the State and other     |
| Government agencies.                                                         |
+------------------------------------------------------------------------------+