U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
01/29/2003 - 01/30/2003
** EVENT NUMBERS **
39533 39534 39539 39542 39545 39546
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39533 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 01/24/2003|
|LICENSEE: GILES ENGINEERING ASSOCIATES |NOTIFICATION TIME: 14:50[EST]|
| CITY: DALLAS REGION: 4 |EVENT DATE: 01/23/2003|
| COUNTY: STATE: TX |EVENT TIME: [CST]|
|LICENSE#: L04919 AGREEMENT: Y |LAST UPDATE DATE: 01/24/2003|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREG PICK R4 |
| |JOHN DAVIDSON IAT |
+------------------------------------------------+SUSAN FRANT NMSS |
| NRC NOTIFIED BY: HELEN WATKINS | |
| HQ OPS OFFICER: MIKE RIPLEY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STOLEN TROXLER MOISTURE DENSITY GAUGE |
| |
| The following information was received from the Texas Department of Health, |
| Bureau of Radiation Control (Texas incident I-7973): |
| |
| "The nuclear gauge was stolen last night. (January 23-24, 2003). It was |
| stolen from an Econoline van parked overnight at an apartment complex. The |
| gauge was locked inside its case and was inside a storage compartment in the |
| cargo area of the locked van. Access was gained by breaking out the windows |
| of the van. |
| |
| "The gauge operator [DELETED] is uncertain of the exact time of the theft. |
| He went out to dinner in his private vehicle and did not notice any problem |
| with the van when he returned home at approximately 8 o'clock in the |
| evening. However, when he stepped outside at 4:30 am to warm up his wife's |
| car, he noticed the Duncanville [Texas] police were on the scene. Three vans |
| parked within about 150 feet of each other, including his, had been |
| burglarized in a similar fashion. One van belonged to an air conditioning |
| company. |
| |
| "The thief took many other items from the van including concrete testing |
| equipment, a coat, measuring tape and a couple of buckets of tools. The |
| gauge and its case were taken. The case is clearly labeled with the |
| company's name and phone number. Inside the case is a full set of paperwork |
| identifying the gauge, a current leak test, and other documents containing |
| the company's letterhead. The police report number is 03000589. The RSO |
| notified Troxler in Arlington [Texas] of the theft." |
| |
| The gauge is a Troxler Model # 3430, Serial # 031693, 40 millicuries |
| Am-241/Be, 8 millicuries Cs-137. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39534 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 01/24/2003|
|LICENSEE: PROFESSIONAL SERVICES INDUSTRIES, INC|NOTIFICATION TIME: 17:53[EST]|
| CITY: CLUTE REGION: 4 |EVENT DATE: 11/25/2002|
| COUNTY: STATE: TX |EVENT TIME: [CST]|
|LICENSE#: L00203-001 AGREEMENT: Y |LAST UPDATE DATE: 01/24/2003|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREG PICK R4 |
| |JOHN HICKEY NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: HELEN WATKINS | |
| HQ OPS OFFICER: MIKE RIPLEY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - DOSIMETRY LEFT IN RADIOGRAPHY AREA |
| |
| The following information was received from the Texas Department of Health, |
| Bureau of Radiation Control (Texas incident I-7972): |
| |
| "During the monitoring period 11/25/2002 through 12/24/2002, radiographer |
| [deleted] left his badge in an area where it was exposed by a radiography |
| crew performing concrete rebar radiography with long exposure times. |
| [deleted] phoned the licensee's corporate offices on January 23, 2003 to |
| report a badge overexposure. At the current time it is thought that the |
| radiographer reported the incident to his supervisor [deleted] RSO in the |
| Clute [TX] Office. The date and time of that report is currently unknown. |
| His badge exposure was measured at 8.266 Rem. A final report has not been |
| received from the badge processor by the Licensee's corporate office, only a |
| Fax transmittal. The corporate office indicated the incident was not |
| previously reported to the corporate office or they would have had the badge |
| submitted for emergency reading." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39539 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: CALIFORNIA RADIATION CONTROL PRGM |NOTIFICATION DATE: 01/27/2003|
|LICENSEE: ISOTOPE PRODUCTS LABORATORIES |NOTIFICATION TIME: 15:16[EST]|
| CITY: BURBANK REGION: 4 |EVENT DATE: 01/23/2003|
| COUNTY: LOS ANGELES STATE: CA |EVENT TIME: 16:30[PST]|
|LICENSE#: CA-1509 AGREEMENT: Y |LAST UPDATE DATE: 01/27/2003|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |WILLIAM JONES R4 |
| |FRED BROWN NMSS |
+------------------------------------------------+TIM MCGINTY IRO |
| NRC NOTIFIED BY: ROBERT GREGER |CREWS NRC |
| HQ OPS OFFICER: GERRY WAIG |JOHN HICKEY NMSS |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - CONTAMINATED PACKAGE |
| |
| The following is taken from a facsimile from the State of California: |
| |
| "On 1/24/03 the RSO [Radiation Safety Officer] @ IPL [Isotope Products |
| Laboratories] reported their receipt of a contaminated package. The package |
| had been picked up from LAX & delivered to IPL on 1/23 @ 2:25 pm by Kamino |
| Int'l Transport, 2580 Santa Fe, Redondo Beach, contact person [DELETED]. The |
| package was wiped upon receipt, and received the results approximately 4:30 |
| pm. The RSO was notified the next morning. The contamination appears to be |
| H-3, although the licensee needs to perform an energy calibration on their |
| liquid scintillation counter to verify both this and their quantification of |
| the package wipes. It appears that all sides of the package were |
| contaminated, at up to approximately 100,000 dpm/wipe. The latest wipes |
| measured up to approximately 40,000 dpm/wipe. |
| |
| "The package came from a company in Switzerland called RC Tritec AG, who is |
| a distributor for a Russian company (unknown name at this time). IPL |
| believes that the box was trans-shipped, & was never actually at Tritec, but |
| they're still trying to get Lufthansa's paperwork. IPL is also trying to get |
| info on the Russian company. |
| |
| "IPL had the delivery truck return to IPL, & they found a small area of |
| contamination, about 12 X 10 inches, on the carpet, where the package was |
| located, of about 800 dpm/wipe. After vacuuming, they got nothing. About 11 |
| other wipes in the truck were negative. They checked the driver's gloves- |
| there's no removable contamination. All wipes @ IPL's Shipping Dept were |
| negative. They think there was at least one other package on the truck that |
| was destined for an electronics company, but they're still trying to get |
| info on that. There was at least one other package for IPL on the truck that |
| was not contaminated (they're checking to see if it had come from the same |
| Russian company). |
| |
| "Note: Assuming that the contamination is H-3, the dose consequences of |
| 100,000 dpm/wipe are approximately equivalent to the dose consequences of |
| 2.5 dpm/wipe of Cs-137." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39542 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 01/28/2003|
| UNIT: [1] [2] [] STATE: PA |NOTIFICATION TIME: 11:39[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 01/28/2003|
+------------------------------------------------+EVENT TIME: 09:30[EST]|
| NRC NOTIFIED BY: DON ROLAND |LAST UPDATE DATE: 01/29/2003|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |DAN HOLODY R1 |
|10 CFR SECTION: | |
|HFIT 26.73 FITNESS FOR DUTY | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PRE-ACCESS CONTRACT SUPERVISOR ACCESS TERMINATED DUE TO A CONFIRMED POSITIVE |
| TEST |
| FOR A CONTROLLED SUBSTANCE. |
| |
| At 09:30 on 01/28/03, a contract supervisor for the turbine upgrade project |
| had a confirmed positive for a controlled substance during a pre-access |
| fitness for duty test. The supervisor's access to the station has been |
| suspended in accordance with the station's fitness for duty program. |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
| |
| * * * UDATE ON 01/29/03 AT 1414 EST FROM DON ROLAND TO GERRY WAIG * * * |
| |
| "Please note the following correction: |
| |
| "The contract supervisor had a confirmed positive test for a controlled |
| substance during a random FFD test, not a pre-access test as previously |
| reported. The error was a result of misinformation provided by the site |
| testing facility to the Control Room. The individual remains suspended and |
| his access to vital areas & work performance while employed at Susquehanna |
| LLC is presently under review. The NRC residents have been notified." |
| |
| Notified R1DO (Dan Holody) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 39545 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WHITING CORPORATION |NOTIFICATION DATE: 01/29/2003|
|LICENSEE: |NOTIFICATION TIME: 14:47[EST]|
| CITY: MONEE REGION: 3 |EVENT DATE: 01/29/2003|
| COUNTY: STATE: IL |EVENT TIME: [CST]|
|LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 01/29/2003|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |KENNETH RIEMER R3 |
| |J. BRADLEY FEWELL R1 |
+------------------------------------------------+KERRY LANDIS R2 |
| NRC NOTIFIED BY: FREDERICK TEGGELAAR |WILLIAM JONES R4 |
| HQ OPS OFFICER: GERRY WAIG |TERRY REIS NRR |
+------------------------------------------------+JOHN HICKEY MNSS |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|CCCC 21.21 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 10 CFR 21 NOTIFICATION - WHITING CORPORATION |
| |
| "This notice is being sent within the two day period to inform you of a |
| safety concern related to Whiting cranes sold to utility companies prior to |
| 1980. The problem was identified through engineering analysis. We are not |
| aware of any failures. |
| |
| "The concern is specific to the Whiting #25 Hoist Unit (Gear Case). One or |
| possibly two internal support bolts in this assembly may be significantly |
| over-stressed. |
| |
| "The exact extent of the over-stressed condition can only be determined by |
| individual analysis of each hoist in question; however, based on findings, a |
| 50% reduction in rated hoist capacity of the effected cranes will allow for |
| continued use of the cranes without compromising design safety factors. This |
| limitation should be enforced until the over-stressed bolts have been |
| replaced or analysis shows that an over-stressed condition does not exist. |
| |
| "Crane owners should contact us at Whiting-Nuclear@WhitingCorp.com and |
| provide the following information; customer name, contact person, email |
| address, telephone number, crane serial number and date of next scheduled |
| outage. |
| |
| "I trust you find that the notification provided is satisfactory and in |
| compliance with 10 CFR 21 reporting requirements. If you have any questions, |
| please do not hesitate to contact me at fteggelaar@whitingcorp. com." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 39546 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 01/29/2003|
| UNIT: [1] [] [] STATE: PA |NOTIFICATION TIME: 20:57[EST]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 01/29/2003|
+------------------------------------------------+EVENT TIME: 20:32[EST]|
| NRC NOTIFIED BY: VAL MANCE |LAST UPDATE DATE: 01/30/2003|
| HQ OPS OFFICER: GERRY WAIG +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: UNUSUAL EVENT |J. BRADLEY FEWELL R1 |
|10 CFR SECTION: |WILLIAM RULAND NRR |
|AAEC 50.72(a) (1) (i) EMERGENCY DECLARED |JOSEPH HOLONICH IRO |
| |DORA HEYMAN FEMA |
| |P.O. BAUMGARTNER EPA |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| NOUE DECLARE AT SUSQUEHANNA DUE TO NON-ROUTINE RADIOACTIVE GAS RELEASE |
| |
| "At 8:32 pm EST PPL Susquehanna , LLC, declared an Unusual Event for an |
| Airborne Release. The EAL entered was 15.1.a A.2, I-131 > 2.08E+2 |
| microcuries/minute. Chemistry sample did not indicate any Iodine in the |
| release steam, however Cs-138 was detected in the sample which may have |
| affected the vent stack monitor. Investigation continues. The release is |
| being monitored by the plant Vent Stack monitoring system. The source of the |
| release is unknown at this time. Plant procedures are being implemented to |
| determine and isolate the source. Offsite monitors have been activated to |
| monitor offsite dose rates. Activation of the Emergency plan and Offsite |
| releases are reportable under 10CFR50.72(a)(1) and 10CFR50.73(a)(2)(viii)." |
| |
| The licensee has notified state and local officials and will notify the NRC |
| Resident Inspector. A media/press release is planned. |
| |
| *** UPDATE at 0132 ET on 01/30/03 by Dave Flyte/ Phil Brady taken by |
| MacKinnon **** |
| |
| Unusual Event was terminated at 0125 ET on 01/30/03. Investigation found |
| that the release was from the off gas system via a drain trap which entered |
| the ventilation system which then exited out the vent stack. According to |
| licensee's records, the release was greater than 2 times their Technical |
| Specification limit (208 microcuries per minute) from 1940 hours until 2111 |
| hours. Max level detected was 600 microcuries per minute. No iodine was |
| released just noble gases. NRC R1DO (Brad Fewell), FEMA (Nora Heyman), |
| NRC/DOT (Petty Officer Baumgartner), Office of Homeland Security (Damon |
| Edwards), and NRR EO (Bill Ruland) notified. |
| |
| The NRC Resident Inspector was notified by the licensee. |
+------------------------------------------------------------------------------+