skip navigation links 
 
 Search Options 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page

Event Notification Report for July 11, 2003


                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/10/2003 - 07/11/2003

                              ** EVENT NUMBERS **

39949  39978  39979  39983  39987  39988  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39949       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE: 06/19/2003|
|LICENSEE:  AGI GEOTECHNICAL                     |NOTIFICATION TIME: 14:30[EDT]|
|    CITY:  VAN NUYS                 REGION:  4  |EVENT DATE:        06/19/2003|
|  COUNTY:                            STATE:  CA |EVENT TIME:        07:30[PDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  07/11/2003|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |DALE POWERS          R4      |
|                                                |DOUG BROADDUS        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  KATHLEEN KAUFMAN             |                             |
|  HQ OPS OFFICER:  HOWIE CROUCH                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CALIFORNIA AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE            |
|                                                                              |
| [DELETED] , Director LA County Radiological Health Management of the CA      |
| Radiological Health Branch and  [DELETED]  Senior Health Physicist           |
| [DELETED] ) called to report that a Moisture Density Gauge (50 milli-Curies  |
| Am-241 and 10 milli-Curies Cs-137) (Manufacture Campbell Pacific, Model MC1, |
| serial # 11114098)  was stolen from a truck at 7:30 AM PDT.  The truck was   |
| at  7-11 in Torrance, California and the driver was inside the 7-11.  The    |
| driver noticed the missing material after he drove away from the 7-11.  The  |
| licensee is AGI Geotechnical  [DELETED] ).  The Torrance Police Department   |
| was notified.                                                                |
|                                                                              |
| * * * UPDATE ON 7/10/03 AT 0707 PM VIA EMAIL FROM R. GREGER * * *            |
|                                                                              |
| "On 6/19/03 AGI Geotechnical, a CA licensee, reported the theft that morning |
| of one of its portable nuclear gauges from a convenience store in Torrance,  |
| CA.  The gauge was taken from the bed of the operator's parked pick-up truck |
| by someone who apparently cut the lock on the chain that locked the gauge to |
| the pickup truck.  The licensee reported the theft to the local police       |
| department and placed an ad in the local press offering a reward for the     |
| return of the gauge.  On 7/7/03 the licensee reported having received a call |
| from an individual in response to the reward ad.  The individual indicated   |
| that he knew who had stolen the gauge and where it was. The licensee         |
| retrieved the gauge that day and returned it to its offices in Van Nuys, CA. |
| A state inspector visited the licensee to physically inspect the gauge and   |
| confirm its identity.  The gauge appeared to be in a normal condition,       |
| undamaged, with no evidence of a radiological hazard.  However, the          |
| transport case for the gauge was cracked in several places and was missing   |
| DOT labels, so it would need to be replaced.  The licensee will have the     |
| gauge checked and leak tested by the manufacturer's service representative   |
| to ensure that the radioactive source was not damaged."                      |
|                                                                              |
| Notified TAS (Whitney) and R4DO (Kennedy).                                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39978       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  COLORADO DEPT OF HEALTH              |NOTIFICATION DATE: 07/07/2003|
|LICENSEE:                                       |NOTIFICATION TIME: 11:04[EDT]|
|    CITY:  DENVER                   REGION:  4  |EVENT DATE:        07/06/2003|
|  COUNTY:  ARAPAHOE                  STATE:  CO |EVENT TIME:        16:00[MDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  07/07/2003|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |KRISS KENNEDY        R4      |
|                                                |MARISSA BAILEY       NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  GREG STASINOS                |                             |
|  HQ OPS OFFICER:  GERRY WAIG                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STOLEN ASPHALT CONTENT OVEN                         |
|                                                                              |
| The following is taken from a facsimile sent from the Colorado Department of |
| Health and Environment:                                                      |
|                                                                              |
| On 7/6/03 at 2230 MDT Robin Koons, Colorado State Department of Health and   |
| Environment, was notified by the Arapahoe County Hazmat Response Team of the |
| theft of an asphalt content oven at a construction site located on Highway   |
| 36, mile marker 119 - 20 miles east of Byers, CO. Arapahoe County Hazmat     |
| responded to initiate an investigation into the incident. Initial            |
| information and indications pointed to a moisture density gauge being        |
| stolen. The moisture density gauge has been found and accounted for. The     |
| asphalt content oven contains a 100 milliCurie (plus or minus 10%) Americium |
| 241:Be source. The oven is used to test for oily content in asphalt during   |
| road construction process. The area is considered a crime scene and has been |
| secured.                                                                     |
|                                                                              |
| Colorado Case Number: 2003-372                                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39979       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TENNESSEE DIV OF RAD HEALTH          |NOTIFICATION DATE: 07/07/2003|
|LICENSEE:  Radiological Assistance, Consulting, |NOTIFICATION TIME: 13:09[EDT]|
|    CITY:  Memphis                  REGION:  2  |EVENT DATE:        06/26/2003|
|  COUNTY:                            STATE:  TN |EVENT TIME:        18:00[EDT]|
|LICENSE#:  R-79266               AGREEMENT:  Y  |LAST UPDATE DATE:  07/07/2003|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOEL MUNDAY          R2      |
|                                                |THOMAS ESSIG         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  Debra Shults                 |                             |
|  HQ OPS OFFICER:  ERIC THOMAS                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT                                                       |
|                                                                              |
| "The [Tennessee Division of Radiological Health] was notified on Monday,     |
| June 30, 2003 by three employees of RACE [Radiological Assistance,           |
| Consulting, & Engineering] of a contamination event that occurred on June    |
| 26, 2003. The employees were sorting and segregating materials contaminated  |
| with low-level radioactive waste. The waste had been delivered to RACE by a  |
| waste broker. The employees ended the shift and frisked for personnel        |
| contamination prior to exiting the building. Several employees alarmed the   |
| PCM and were decontaminated prior to release. One employee had high levels   |
| of skin contamination and underwent several hours of decontamination.        |
| Preliminary results from urinalyses are negative according to the licensee.  |
| The employees are undergoing whole body counts today. The shop area was      |
| closed for routine business and decontaminated.  It was opened on Sunday,    |
| June 29, 2003. DRH staff from Memphis and Nashville visited the site to      |
| begin the investigation. Staff continue to investigate and will continue to  |
| keep the NRC informed of the status of our investigation. This incident is   |
| reportable under 1200-2-5.141 (2)(c)1(i) of 'State Regulations for           |
| Protection Against Radiation.'"                                              |
|                                                                              |
| Tennessee Report ID:  TN-03-100                                              |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39983       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 07/08/2003|
|LICENSEE:  GUIDANT CORPORATION                  |NOTIFICATION TIME: 15:28[EDT]|
|    CITY:  PEARLAND                 REGION:  4  |EVENT DATE:        06/19/2003|
|  COUNTY:                            STATE:  TX |EVENT TIME:             [CDT]|
|LICENSE#:  L05178-000            AGREEMENT:  Y  |LAST UPDATE DATE:  07/08/2003|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |KRISS KENNEDY        R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  HELEN WATKINS                |                             |
|  HQ OPS OFFICER:  ERIC THOMAS                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT                                                       |
|                                                                              |
| Spill of radioactive material.  On 6/19/2003, an employee inadvertently      |
| dropped a vial of P-32 on the floor.  The container spilled approximately    |
| 2900 millicuries of P-32 on the floor while contaminating one employee and   |
| several pieces of the licensee's equipment.  The employee was decontaminated |
| on site.  An initial clean-up wash was performed on the facility.  However,  |
| the radiation levels remained high.  The RSO (Radiation Safety Officer)      |
| directed that the floors be covered with 2 sheets of 4 ft by 8 ft plexiglas. |
| In addition, the licensee covered contaminated equipment with lead sheeting  |
| to prevent  the spread of contamination and elevated radiation levels in the |
| vicinity of the equipment.  The licensee is waiting 10 half-lives to release |
| the facility for full use.  All personnel entering the area are notified of  |
| the contamination and are warned of the radiation levels and potential       |
| contamination.                                                               |
|                                                                              |
| The incident was not reported within 24 hours per regulations.  Levels       |
| exceed release criteria.  The incident is being investigated.                |
|                                                                              |
| This incident is being reported under 10 CFR 30.50(b)(1), and Texas          |
| requirement 289.202(xx)(7)(A).                                               |
|                                                                              |
| Texas incident number I-8034.                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39987       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 07/10/2003|
|    UNIT:  [] [2] [3]                STATE:  IL |NOTIFICATION TIME: 04:03[EDT]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        07/09/2003|
+------------------------------------------------+EVENT TIME:        22:00[CDT]|
| NRC NOTIFIED BY:  RON WIGGINS                  |LAST UPDATE DATE:  07/10/2003|
|  HQ OPS OFFICER:  HOWIE CROUCH                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CHRIS MILLER         R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       99       Power Operation  |99       Power Operation  |
|3     N          Y       99       Power Operation  |99       Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CONTROL ROOM HVAC REFRIGERATION AND CONDENSING UNIT TRIPPED DURING           |
| SURVEILLANCE TEST                                                            |
|                                                                              |
| "At 2200 hours on July 9, 2003, the B Control Room HVAC Refrigeration and    |
| Condensing Unit (RCU) tripped and would not stay running during surveillance |
| testing.  The RCU is a single train system and therefore is reportable per   |
| SAF 1.8 and LS-AA-1400, Event Reporting Guidelines Section 3.2.7.  The RCU   |
| is required to operate during a design basis accident to remove heat from    |
| the Main Control Room.  The Air Filtration Unit (AFU) of CREVS [Control Room |
| Emergency Ventilation System] remains operable.  This places both units in a |
| 30 day LCORA [Limiting Condition for Operation Required Action] per Tech     |
| Spec 3.7.5 Required Action A.1."                                             |
|                                                                              |
| The licensee has notified the NRC Resident Inspector.                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39988       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 07/10/2003|
|    UNIT:  [] [2] []                 STATE:  WI |NOTIFICATION TIME: 15:55[EDT]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        07/10/2003|
+------------------------------------------------+EVENT TIME:        13:44[CDT]|
| NRC NOTIFIED BY:  ROB HARRSCH                  |LAST UPDATE DATE:  07/10/2003|
|  HQ OPS OFFICER:  BILL GOTT                    +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CHRIS MILLER         R3      |
|10 CFR SECTION:                                 |TERRY REIS           NRR     |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     A/R        Y       100      Power Operation  |0        Hot Standby      |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AUTOMATIC REACTOR TRIP DUE TO MAIN FEEDWATER PUMP TRIP                       |
|                                                                              |
| "At 1342, The Unit 2 'B' Main Feedwater Pump tripped, this was followed by   |
| an automatic reactor trip at 1344.  All Reactor Protection and Safety        |
| Systems responded as required.  The Unit 2 'B' Heater Drain Tank Pump also   |
| tripped during the transient.  The 'B' Main Feedwater Pump trip was due to   |
| an electrical fault, the cause is unknown at this time. Unit 2 is stable in  |
| Mode 3 at this time."                                                        |
|                                                                              |
| Additionally, due to the initial low levels in the Unit 2 Steam Generators   |
| due to the Main Feedwater Pump trip,  Auxiliary Feed Water initiated as      |
| expected.                                                                    |
|                                                                              |
| The licensee reported that all rods fully inserted, decay heat is being      |
| removed by dumping steam to the main condenser, and no primary or secondary  |
| relief valves lifted..                                                       |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+