U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
05/13/2003 - 05/14/2003
** EVENT NUMBERS **
39843
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 39843 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: NUCOR STEEL |NOTIFICATION DATE: 05/13/2003|
|LICENSEE: NUCOR STEEL |NOTIFICATION TIME: 13:14[EDT]|
| CITY: CRAWFORDSVILLE REGION: 3 |EVENT DATE: 05/12/2003|
| COUNTY: STATE: IN |EVENT TIME: 15:00[CST]|
|LICENSE#: 13-25975-01 AGREEMENT: N |LAST UPDATE DATE: 05/13/2003|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |SONIA BURGESS R3 |
| |FRED BROWN NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JEFF JORDAN | |
| HQ OPS OFFICER: HOWIE CROUCH | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|ISAF 30.50(b)(2) SAFETY EQUIPMENT FAILUR| |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| METAL THICKNESS GAUGE SHUTTER ASSEMBLY DAMAGED |
| |
| On 5/12/03 at 1500 CST, the shutter assembly on an IMS model TIAS-04 metal |
| thickness gauge became stuck and resulted in shutter assembly bolts |
| shearing. The gauge contains 50 curies of Cs-137. The licensee safed the |
| gauge by isolating air to the air-operated gauge. The manufacturer was |
| contacted and is currently on-site repairing the gauge. Additionally, |
| during the incident, the assistant RSO walked below the gauge without having |
| his radiation detection meter. Ion chambers mounted in the gauge area were |
| reading zero at the time. Area monitors mounted in the area were not in |
| alarm. The RSO has sent the assistant RSO's film badge out for processing. |
| |
| |
| The licensee has contacted Region 3 personnel (Sandy Frazier and Debbie |
| Piskura). |
+------------------------------------------------------------------------------+