U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
06/21/1999 - 06/22/1999
** EVENT NUMBERS **
35849 35850
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 35849 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY REGION: 2 |NOTIFICATION DATE: 06/21/1999|
| UNIT: [] [2] [] STATE: AL |NOTIFICATION TIME: 18:53[EDT]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 06/21/1999|
+------------------------------------------------+EVENT TIME: 16:57[CDT]|
| NRC NOTIFIED BY: BOWEN |LAST UPDATE DATE: 06/21/1999|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CAUDLE JULIAN R2 |
|10 CFR SECTION: | |
|ASHU 50.72(b)(1)(i)(A) PLANT S/D REQD BY TS | |
|NLCO TECH SPEC LCO A/S | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| THE PLANT ENTERED TS REQUIRED SHUT DOWN DUE TO LOSS OF TWO STEAM FLOW |
| CHANNELS ON THE "A" STEAM GENERATOR. |
| |
| PRIOR TO THIS EVENT THERE WAS A BROKEN SENSING LINE ON THE "B" STEAM |
| GENERATOR STEAM FLOW CHANNEL WHICH REQUIRED PUTTING THE CHANNEL 3 STEAM |
| FLOWS ON ALL THREE STEAM GENERATORS IN TEST. TODAY @ 1657 CHANNEL 4 ON THE |
| "A" STEAM GENERATOR FAILED. THERE ARE TWO STEAM FLOW CHANNELS PER STEAM |
| GENERATOR AND TECHNICAL SPECIFICATIONS REQUIRE ONE OF THE TWO FLOW CHANNELS |
| TO BE AVAILABLE. SINCE CHANNELS 3 AND 4 ON THE "A" STEAM GENERATOR ARE NOT |
| AVAILABLE, THE PLANT ENTERED TS LCO 3.0.3 WHICH GIVES THEM 7 HRS. TO BE IN |
| HOT STANDBY, 6 HOURS TO HOT SHUTDOWN AND THE FOLLOWING 24 HOURS TO COLD |
| SHUTDOWN. THE FEED PUMP SPEED CONTROL AND THE "A" STEAM GENERATOR FLOW |
| CONTROL VALVE WERE PLACED IN MANUAL AND LEVELS WERE STABILIZED. THEY CAN |
| EXIT THE LCO ACTION STATEMENT IF THEY TAKE CHANNEL 3 OUT OF TEST ON "A" |
| STEAM GENERATOR AND RETURN IT TO SERVICE. |
| |
| THE RESIDENT INSPECTOR WILL BE INFORMED. |
| |
| *** UPDATE ON 6/21/99 @ 2017 BY BOWEN TO GOULD *** |
| |
| THEY TOOK THE CHANNEL 3 STEAM FLOW OUT OF TEST AND RETURNED IT TO SERVICE AT |
| 1807 AND EXITED THE LCO ACTION STATEMENT. |
| |
| THE RESIDENT WILL BE NOTIFIED. REG2 RDO (JULIAN) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 35850 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WILCOX ASSOCIATES |NOTIFICATION DATE: 06/21/1999|
|LICENSEE: WILCOX ASSOCIATES |NOTIFICATION TIME: 19:06[EDT]|
| CITY: CADILAC REGION: 3 |EVENT DATE: 06/21/1999|
| COUNTY: STATE: MI |EVENT TIME: 15:30[EDT]|
|LICENSE#: 21-23314-01 AGREEMENT: N |LAST UPDATE DATE: 06/21/1999|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MIKE JORDAN R3 |
| | |
+------------------------------------------------+ |
| NRC NOTIFIED BY: PIERCE | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NDAM DAMAGED GAUGE/DEVICE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| TROXLER GAUGE DAMAGED. |
| |
| A MODEL 3440A TROXLER GAUGE CONTAINING 8 MILLICURIES OF CESIUM-137 AND 40 |
| MILLICURIES OF AMERICIUM-241 WAS DAMAGED WHEN IT WAS RUN OVER ON U.S. ROUTE |
| 23 NEAR PAWAS, MI. THERE APPEARS TO BE NO DAMAGE TO THE SOURCE. THEY ARE |
| PLANNING ON PUTTING IT INTO ITS STORAGE CASE AND TAKING IT BACK TO THEIR |
| FACILITIES. |
+------------------------------------------------------------------------------+