skip navigation links 
 
 Search Options 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page
Consolidated Line Item Improvement Process (CLIIP)
Proposed Technical Specification Changes Open for Comment
CLIIP STS Changes Issued for Adoption

Proposed Technical Specification Changes Open for Comment

To submit comments or questions on a proposed standard technical specification change, use our Form for Sending Comments on NRC Documents, then select Proposed Changes to Technical Specifications. If you are commenting on a proposed change, please help us match your comments with the correct proposed change by copying the title of the proposed change from column one to the previous table into the appropriate field of the comment form. To send us other comments or questions related to technical specifications, see our Contact Us page.

Some links on this page are to documents in our Agencywide Documents Access and Management System (ADAMS), and others are to documents in Adobe Portable Document Format (PDF). ADAMS documents are provided in either PDF or Tagged Image File Format (TIFF). To obtain free viewers for displaying these formats, see our Plugins, Viewers, and Other Tools page. If you have questions about search techniques or problems with viewing or printing documents from ADAMS, please contact the Public Document Room staff.

Title of Proposed Change Applicability --based on Nuclear Supply System Vendor (Reactor Type) Federal Register
Notice exit icon
Comment Period Start Date*
TSTF-426, Revision 0, "Revise or Add Actions to Preclude Entry into LCO 3.0.3 -RITSTF Initiatives 6b & 6c"
ML042520158
This Traveler supports NEI Risk Informed Technical Specification Task Force (RITSTF) Initiative 6b, "Provide Conditions in the LCOs for Those Levels of Degradation Where No Condition Currently Exists to Preclude Entry Into LCO 3.0.3," and 6c, "Provide Specific Times in the LCO For Those Conditions That Require Entry Into LCO 3.0.3 Immediately," for Combustion Engineering plants 71 Fed. Reg. 41264-41280

[HTML]   [PDF]

July 20, 2006

TSTF-477, Revision 3, "Add an Action for Two Inoperable Control Room AC Subsystems."
ML062510321
For Boiling Water Reactors, the proposed changes would revise Technical Specification 3.7.5 (3.7.4 for BWR/6) "Control Room Air Conditioning (AC) System" to add an action statement for two inoperable control room subsystems. 71 Fed. Reg. 75774�777

[HTML]   [PDF]

December 18, 2006

TSTF-490, Rev. 0, Deletion of E Bar Definition and Revision to RCS Specific Activity
ML052630462
Revises the RCS specific activity specification for pressurized water reactors to utilize a new indicator, Dose Equivalent Xenon-133 instead of the current indicator known as E Bar. 71 Fed. Reg. 67170�175

[HTML]   [PDF]

November 20, 2006

*Comment periods are normally 30 days. Subsequent comments will be considered if it is practical to do so.



Privacy Policy | Site Disclaimer
Tuesday, February 13, 2007