Mechanical Measurements

Acoustic Measurements

Technical Contacts:
Victor Nedzelnitsky
Tel: 301/975-6638
E-mail: victor.nedzelnitsky@nist.gov

Randall P. Wagner
Tel: 301/975-6619
E-mail: randall.wagner@nist.gov

David J. Evans
Tel: 301/975-6637
E-mail: david.evans@nist.gov

Do not ship instruments or standards to the mailing address listed below.  Contact the technical staff for the shipping address. 

Mailing Address:
National Institute of Standards and Technology
100 Bureau Drive, Stop 8221
Gaithersburg, MD 20899-8221

Service ID
Number
Description of Services Fee ($)
25010C Pressure Response: WE Type 640AA microphones or equivalent (e.g., Tokyo Riko Type ECL MR103; Bruel & Kjaer Type 4160, Bruel & Kjaer Types 4144 or 4132 with DB0111 adapter), 50 Hz to 10 000 Hz. 6215
25020C Pressure Response: WE Type 640AA microphones or equivalent (e.g., Tokyo Riko Type ECL MR103; Bruel & Kjaer Type 4160; Bruel & Kjaer Types 4144 or 4132 with DB0111 adapter), 50 Hz to 20 000 Hz. 7451
25030C Pressure Response: Tokyo Riko Type ECL MR112; Bruel & Kjaer Type 4134, or equivalent half-inch microphones, 50 Hz to 10 000 Hz. 7158
25040C Pressure Response: Tokyo Riko Type EC MR112, Bruel & Kjaer Type 4134, or equivalent half-inch microphones, 50 Hz to 20 000 Hz. 8960
25050C Free-Field Response: Tokyo Riko Type ECL MR112, Bruel & Kjaer Types 4133, 4134, 4165, 4166, 4180, or equivalent half-inch microphones, 2500 Hz to 20 000 Hz. 6983
25060S Special Tests of Acoustic Devices At Cost
25070S Special Tests of Audiometers/Earphones 5970
Fees are subject to change without notice.

back to top of page | back to index of mechanical measurements

Pressure and Free-Field Responses of Microphones (25010C-25050C)

Pressure calibrations (Service ID Nos. 25010C and 25020C) are performed on Type-L one-inch microphones* satisfying the requirements of American National Standard S1.12-1967 (R1977), Specifications for Laboratory Standard Microphones and its impending revision. The microphones submitted for pressure calibration must be suitable for use with the calibrating couplers shown in Figures 6 and 10 of the applicable American National Standard S1.10-1966 (R1986).

* Type-L one-inch is a commercial designation for these microphones.

Further information is contained in the references for acoustic measurements.

Since American National Standards Institute publications S1.10-1966 (R1986) and S1.12-1967 (R1977) were issued, certain types of half-inch diameter precision microphones have attained widespread use. Therefore, NIST has developed procedures (Service ID Numbers 25030C and 25040C) for determining the pressure response levels of half-inch microphones by comparison with NIST-owned Type-L standard microphones, which in turn are calibrated periodically by the reciprocity technique. The technique used, precautions to be observed, and uncertainties of measurement are essentially the same as those given above for one-inch microphones. Significantly different aspects of the procedures for half-inch microphones, such as ground shield configuration, are described in the test report. Since several half-inch laboratory standard microphones have been available for only a relatively short time, their long-term stability has yet to be determined.

The free-field response levels of certain Type L microphones (e.g., Western Electric Type 640AA condenser microphones) can be computed from pressure response levels reported by NIST. However, certain precautions must be taken, and there is some degradation in accuracy.

Therefore, for the most demanding free-field measurement requirements, NIST offers a calibration service (Service ID No. 25050C) for determining the free-field response levels for half-inch microphones. The calibrations are made over the frequency range of 2.5 kHz to 20 kHz at normal incidence. Response levels (sensitivity levels) are reported in terms of open-circuit voltage per unit sound pressure (in the absence of the microphone) of a plane progressive wave whose direction of propagation is normal to the plane of the diaphragm. The calibrations are performed in a well-characterized anechoic chamber. A typical expanded uncertainty in this calibration is approximately 0.21 dB or less at each frequency within the range of 2.5 kHz to 6.3 kHz and 0.15 dB or less at each frequency within the range of 6.3 kHz to 20 kHz. Calibrations can be performed with or without protective grids on the microphone. For the most precise free-field measurements, the customer should contact the NIST staff person cited at the beginning of this section for recommendations prior to submitting the microphone to NIST for calibration.

back to top of page | back to index of mechanical measurements

Special Tests of Acoustic Devices (25060S)

Acoustical measurement services are available by special arrangement. These services include extended frequency ranges of calibration, additional data points, measurements at very low sound pressure levels, and calibration of certain pistonphones and acoustic calibrators. NIST has a large general-purpose anechoic chamber available for special calibrations requiring such a facility. The frequency-dependent and position-dependent acoustical performance of this chamber, including extremely low background noise, was carefully controlled during design and construction and is documented in archival journal publications.

back to top of page | back to index of mechanical measurements

Special Tests of Audiometers/Earphones (25070S)

Earphones are tested on the NIST 9-A Coupler from 125 Hz to 8000 Hz. Measurements of audiometer/earphone response and linearity can be made at very low sound pressure levels.

back to top of page
| back to index of mechanical measurements


References-Acoustic Measurements

Calibration of Pressure and Gradient Microphones , V. Nedzelnitsky, Encyclopedia of Acoustics, Ed. in Chief M. J. Crocker, John Wiley & Sons, Inc., New York, 1869-1879 (1997).

Primary Method for Free-Field Calibration, V. Nedzelnitsky , AIP Handbook of Condenser Microphones, Eds., G. S. K. Wong and T. F. W. Embleton, Am. Inst. of Physics Press, Woodbury, NY, 103-109 (1995).

Laboratory Microphone Calibration Methods at the National Institute of Standards and Technology, U.S.A. , V. Nedzelnitsky, AIP Handbook of Condenser Microphones, Eds., G. S. K. Wong and T. F. W. Embleton, Am. Inst. of Physics Press, Woodbury, NY, 145-161 (1995).

Method for Calibration of Microphones, Amer. Natl. Stand. Inst. S1.10-1966 (R1986), New York, NY.

Specifications for Laboratory Standard Microphones, Amer. Natl. Stand. Inst. S1.12-1967 (R1977), New York, NY.

Free-Field Reciprocity Calibration of Microphones, E. D. Burnett and V. Nedzelnitsky, J. Res. Natl. Bur. Stand. (U.S.) 92 (2), 129 (Mar.-April 1987).

Traceability of Acoustical Instrument Calibration to the National Bureau of Standards , V. Nedzelnitsky, Proc. INTER-NOISE 80, II, Dec. 8-10, 1980, Miami, FL, G. C. Maling, Jr., Ed., Poughkeepsie, NY: Noise Control Foundation, 1043 (1980).

Calibration of Laboratory Condenser Microphones, V. Nedzelnitsky, E. D. Burnett, and W. B. Penzes, Proc. 10th Transducer Workshop, Transducer Committee, Telemetry Group, Range Commanders Council, Colorado Springs, CO (June 1979).

Acoustical Properties of the National Bureau of Standards Anechoic Chamber , W. Koidan and G. R. Hruska, J. Acoust. Soc. Am. 64 (2), 501 (Aug. 1978).

back to top of page
| back to index of mechanical measurements

Date created: 06/30/1999
Last updated: 01/18/2007

Program questions: Calibrations

Phone: (301) 975-2200, Fax: (301) 869-3548

NIST, 100 Bureau Drive, Stop 2300, Gaithersburg, MD 20899-2300

If you have any questions regarding this website, or notice any problems or inaccurate information, please contact the webmaster by sending e-mail to: TSWeb@nist.gov
NIST is an agency of the U.S. Department of Commerce.