Unplanned Scrams per 7000 Critical Hrs 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Unplanned scrams 0 0 0 0 1.0 0 1.0 0
Critical hours 2208.0 2209.0 1264.9 2184.0 2171.9 2209.0 2132.0 2060.5
                 
Indicator value 0.8 0.8 0.9 0 0.9 0.9 1.6 1.6


Licensee Comments: none




Link to Notes

Unplanned Power Changes per 7000 Critical Hrs 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Unplanned power changes 0 0 0 0 0 1.0 0 0
Critical hours 2208.0 2209.0 1264.9 2184.0 2171.9 2209.0 2132.0 2060.5
                 
Indicator value 0 0 0 0 0 0.9 0.8 0.8

Licensee Comments: none






Link to Notes

Unplanned Scrams with Complications 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Scrams with complications   0 0 0 0 0 1.0 0
                 
                 
Indicator value         0.0 0.0 1.0 1.0

Licensee Comments: none






Link to Notes

Safety System Functional Failures (BWR) 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Safety System Functional Failures 1 0 0 1 1 0 0 1
                 
Indicator value 2 2 1 2 2 2 2 2

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Emergency AC Power System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) 5.00E-08 1.20E-08 8.30E-09 2.90E-08 3.50E-09 -1.20E-08 -1.30E-08 5.10E-09
URI (ΔCDF) -7.70E-08 1.70E-08 2.20E-08 7.30E-08 -2.20E-08 -1.20E-07 -2.40E-07 -2.80E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -2.70E-08 2.90E-08 3.03E-08 1.02E-07 -1.85E-08 -1.32E-07 -2.53E-07 -2.75E-07

Licensee Comments:

2Q/08: Changed PRA Parameter(s). UABLP values updated based on MSPI Basis Document revision approved 03/31/08.






Link to Notes

Mitigating Systems Performance Index, High Pressure Injection System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) 5.40E-09 8.10E-09 -1.60E-08 6.00E-09 5.50E-09 5.40E-09 2.20E-07 3.70E-08
URI (ΔCDF) -1.50E-07 -1.60E-07 4.50E-07 1.50E-06 1.50E-06 1.50E-06 2.10E-06 2.10E-06
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -1.45E-07 -1.52E-07 4.34E-07 1.51E-06 1.51E-06 1.51E-06 2.32E-06 2.14E-06

Licensee Comments:

2Q/08: Risk Cap Invoked. Changed PRA Parameter(s). UABLP values updated based on MSPI Basis Document revision approved 03/31/08.






Link to Notes

Mitigating Systems Performance Index, Heat Removal System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) 1.50E-07 -6.90E-08 -5.80E-08 -5.70E-08 -5.80E-08 -5.80E-08 -7.10E-08 -7.10E-08
URI (ΔCDF) -1.60E-07 -1.50E-07 -1.50E-07 -1.50E-07 -1.50E-07 -1.50E-07 -1.80E-07 -1.80E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -1.00E-08 -2.19E-07 -2.08E-07 -2.07E-07 -2.08E-07 -2.08E-07 -2.51E-07 -2.51E-07

Licensee Comments:

2Q/08: Changed PRA Parameter(s). UABLP values updated based on MSPI Basis Document revision approved 03/31/08.






Link to Notes

Mitigating Systems Performance Index, Residual Heat Removal System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) -1.00E-08 -8.50E-09 -7.60E-09 -6.10E-09 -6.20E-09 -7.10E-09 -7.20E-09 -7.20E-09
URI (ΔCDF) -6.30E-08 2.20E-08 1.80E-08 1.00E-07 1.10E-07 1.20E-07 1.20E-07 1.20E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -7.30E-08 1.35E-08 1.04E-08 9.39E-08 1.04E-07 1.13E-07 1.13E-07 1.13E-07

Licensee Comments:

2Q/08: Changed PRA Parameter(s). UABLP values updated based on MSPI Basis Document revision approved 03/31/08.






Link to Notes

Mitigating Systems Performance Index, Cooling Water Systems 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
UAI (ΔCDF) 2.60E-08 1.90E-07 3.20E-08 3.60E-08 3.60E-08 4.00E-08 6.20E-08 4.40E-08
URI (ΔCDF) -9.80E-08 -1.00E-07 -9.80E-08 -9.90E-08 -9.90E-08 -1.00E-07 -1.10E-07 -8.70E-08
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -7.20E-08 9.00E-08 -6.60E-08 -6.30E-08 -6.30E-08 -6.00E-08 -4.80E-08 -4.30E-08

Licensee Comments:

2Q/08: Changed PRA Parameter(s). UABLP values updated based on MSPI Basis Document revision approved 03/31/08.






Link to Notes

Reactor Coolant System Activity 7/06 8/06 9/06 10/06 11/06 12/06 1/07 2/07 3/07 4/07 5/07 6/07
Maximum activity 0.000010 0.000012 0.000009 0.000011 0.000009 0.000008 0.000010 0.000006 0.000010 0.000010 0.000006 0.000006
Technical specification limit 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
                         
Indicator value 0 0 0 0 0 0 0 0 0 0 0 0
Reactor Coolant System Activity 7/07 8/07 9/07 10/07 11/07 12/07 1/08 2/08 3/08 4/08 5/08 6/08
Maximum activity 0.000007 0.000006 0.000006 0.000012 0.000005 0.000006 0.000005 0.000007 0.000006 0.000006 0.000004 0.000005
Technical specification limit 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
                         
Indicator value 0 0 0 0 0 0 0 0 0 0 0 0

Licensee Comments: none






Link to Notes

Reactor Coolant System Leakage 7/06 8/06 9/06 10/06 11/06 12/06 1/07 2/07 3/07 4/07 5/07 6/07
Maximum leakage 1.900 1.850 1.860 1.840 1.820 1.840 1.810 1.790 1.680 1.780 1.770 1.710
Technical specification limit 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0
                         
Indicator value 6.3 6.2 6.2 6.1 6.1 6.1 6.0 6.0 5.6 5.9 5.9 5.7
Reactor Coolant System Leakage 7/07 8/07 9/07 10/07 11/07 12/07 1/08 2/08 3/08 4/08 5/08 6/08
Maximum leakage 1.730 1.750 1.730 1.730 1.720 1.720 1.720 1.740 1.750 1.710 1.730 1.720
Technical specification limit 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0
                         
Indicator value 5.8 5.8 5.8 5.8 5.7 5.7 5.7 5.8 5.8 5.7 5.8 5.7

Licensee Comments: none






Link to Notes

Drill/Exercise Performance 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Successful opportunities 34.0 24.0 2.0 11.0 72.0 7.0 6.0 30.0
Total opportunities 41.0 24.0 2.0 12.0 73.0 7.0 6.0 32.0
                 
Indicator value 92.3% 93.2% 93.8% 93.1% 94.3% 94.5% 94.5% 94.4%

Licensee Comments: none






Link to Notes

ERO Drill Participation 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Participating Key personnel 133.0 134.0 132.0 130.0 138.0 136.0 137.0 134.0
Total Key personnel 135.0 137.0 134.0 135.0 140.0 137.0 137.0 134.0
                 
Indicator value 98.5% 97.8% 98.5% 96.3% 98.6% 99.3% 100.0% 100.0%

Licensee Comments: none






Link to Notes

Alert & Notification System 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
Successful siren-tests                
Total sirens-tests                
                 
Indicator value                

Licensee Comments:

2Q/08: Plant Hatch does not use sirens as an emergency notification system.






Link to Notes

Occupational Exposure Control Effectiveness 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
High radiation area occurrences 0 0 0 0 0 0 0 0
Very high radiation area occurrences 0 0 0 0 0 0 0 0
Unintended exposure occurrences 0 0 0 0 0 0 0 0
Indicator value 0 0 0 0 0 0 0 0

Licensee Comments: none






Link to Notes

RETS/ODCM Radiological Effluent 3Q/06 4Q/06 1Q/07 2Q/07 3Q/07 4Q/07 1Q/08 2Q/08
RETS/ODCM occurrences 0 0 0 0 0 0 0 0
                 
Indicator value 0 0 0 0 0 0 0 0

Licensee Comments: none






Physical Protection information not publicly available.



 
 
 
 

Top of page    Action Matrix Summary |  Inspection Findings Summary |  PI Summary |  Reactor Oversight Process