Dimensional Measurements

Angular Measurements

Technical Contacts:
Bryon S. Faust
Tel: 301/975-4351
E-mail: bryon.faust@nist.gov

Theodore D. Doiron
Tel: 301/975-3472
E-mail: theodore.doiron@nist.gov

Do not ship instruments or standards to the mailing address listed below. Contact the technical staff for the shipping address.

Mailing Address:
National Institute of Standards and Technology
100 Bureau Drive, Stop 8211
Gaithersburg, MD 20899-8211

Service ID
Number
Description of Services Fee ($)
14010C
Angle Gage Blocks: Set Up Charge, per order
164
14011C
Angle Block, per Block
161
14020S
Special Tests of Optical Polygons
At Cost
14030S
Special Tests of Rotary and Indexing Tables: Every 30°
2281
14031S
Special Tests of Rotary and Indexing Tables: (30° , 5°, 1° ) Calibration
4441
14040S
Special Tests of Optical Wedges: Fixed-Angle Wedge
786
14041S
Special Tests of Optical Wedges: Variable-Angle Wedge
At Cost
14050S
Special Angular Measurements, by Prearrangement
At Cost
Fees are subject to change without notice.

back to top | back to index of dimensional measurements

Angle Gage Blocks (14010C-14011C)

Angle blocks are measured in an angle comparator system consisting of a special chamber and two autocollimators. The blocks are placed in the chamber to minimize air currents and stray light effects. The test blocks are compared to NIST master angle blocks following an intercomparison method to eliminate thermal drift. Measurements are made in both top up and bottom up positions. Check standard blocks are measured during the procedure as well as for process control. Standard size block sets include (1-, 3-, 5-, 20-, and 30-) sizes; (1", 3", 5", 20", and 30") sizes; and 1°, 3°, 5°, 15°, 30°, and 45° sizes.

The expanded uncertainty for this calibration is approximately 0.18" for ideal blocks. However, this value varies with the condition and geometry of the test block gaging surfaces. Customer angle blocks with poor gaging surfaces blocks can have uncertainties as high as 0.3" to 0.4". Angle blocks with dimensions other than standard (1 inch by 2 inch (2.54 cm by 5.08 cm) in measuring faces) require different measurement methods and generally result in higher uncertainties.

All angle blocks submitted for calibration should be in substantially new block condition, and each marked with an identification number. In shipping angle blocks, the same care exercised in gage block shipment should be used.

back to top | back to index of dimensional measurements

Special Tests of Optical Polygons (14020S)

NIST provides special tests for optical polygons. Optical polygons are calibrated using an indexing table stack, an autocollimator and circle closure measurement techniques. Polygons with nominally equal angles between faces are normally measured by closure.

The expanded uncertainty for this calibration is approximately 0.14"; however, this value varies with the condition and geometry of the polygon faces. The technical contact must be consulted before this special test is requested.

back to top | back to index of dimensional measurements

Special Tests of Rotary and Indexing Tables (14030S-14031S)

NIST provides special tests for rotary and indexing tables. Indexing tables (limited, fixed-increment, high repeatability). These tables and rotary tables (continuous increment, low repeatability) are calibrated using an autocollimator and reflecting target, an indexing table stack, and circle closure techniques. The standard set of angular increments is every 30°. Additionally, every 5° of the first 30° interval, and every 1° of the first 5° interval can be measured. Check standard indexing tables are used for process control during the measurement procedure. Indexing tables must be less than a maximum 254 mm (10 inch) in diameter.

The expanded uncertainty for this calibration is approximately 0.14", however, this value varies with the locking mechanism repeatability and the scheme of angles chosen to be measured. The technical contact must be consulted before this special test is requested.

back to top | back to index of dimensional measurements

Special Tests of Optical Wedges (14040S-14041S)

NIST provides special tests to calibrate optical wedges. Optical wedges are calibrated using an autocollimator, a reflecting target, the test wedge and a repeated reversal measurement series. Fixed angle and adjustable wedges can be calibrated. The wedge is inserted between the autocollimator and reflecting target and measured. The wedge is removed, rotated 180° about the same base, reinserted and measured. In this reversal technique the difference in the two measurements is equal to twice the actual angle. Check standard wedges are measured for process control.

The expanded uncertainty for this calibration is approximately 0.12". However, this value varies with condition and geometry of the wedge surfaces. The technical contact must be consulted before this special test is requested.

back to top | back to index of dimensional measurements

Special Angular Measurements, by Prearrangement (14050S)

For angular measurement requirements not covered by the services described above, special arrangements may be made by contacting Engineering Metrology Staff 301/975-3471. Requests for service will be discussed and honored if current equipment and means are available. Artifacts such as optical squares (pentaprisms), apex angle measurements of prisms, true squares, and polygons not already described, typically fall into this category.

back to top | back to index of dimensional measurements


References-Angular Measurements

Uncertainty and Dimensional Calibrations , Ted Doiron, John R. Stoup, J. Res. Natl. Inst. Stand. Technol. 102 (6) 647 (1997).

The Calibration of Angle Blocks by Intercomparison , C. P. Reeve, Natl. Bur. Stand. (U.S.), NBSIR 80-1967 (1980).

The Calibration of Indexing Tables by Subdivision , C. P. Reeve, Natl. Bur. Stand. (U.S.), NBSIR 75-750 (1975).

back to top | back to index of dimensional measurements


Date created: 06/30/1999
Last updated: 01/17/2008


Program questions: Calibrations

Phone: (301) 975-2200, Fax: (301) 869-3548