Tower Temperature and Humidity Sensors (TWR)
Instrument Categories: Surface Meteorology, Atmospheric Profiling
General Overview
Three tall towers are installed at Atmospheric Radiation Measurement Climate Research Facility (ACRF) sites: a 60-m triangular tower at the Southern Great Plains (SGP) Central Facility (CF), a 21 m walkup scaffolding tower at the SGP Okmulgee forest site (E21), and a 40-m triangular tower at the North Slope of Alaska (NSA) at Barrow. The towers are used for meteorological, radiological, and other measurements. Instrument systems installed on the towers are listed in section 7, Instrument Details, although only the Temperature/Relative Humidity/Vapor Pressure (T/RH/VP) measurements made on the SGP CF tower are described in detail. Information on measurements made by the other instrument systems on the towers can be found at individual instrument systems web pages.
Primary Measurements Taken
The following measurements are those considered scientifically relevant. Refer to the netCDF File Header Descriptions (Data Object Design Files) for the list of all available measurements, including those recorded for diagnostic or quality assurance purposes.
Available Value-Added Products
This instrument is an input to the following value-added products, which provide improved measurements or derived quantities.
- 1twrmr - Sixty Meter Tower: mixing ratio at surface, 25-m, and 60-m, 1-min average
- 30twrmr - Sixty meter tower: mixing ratio at surface, 25-m, and 60-m, 30-min avg
Available Datastreams
- 1440twr21x - Sixty Meter Tower: daily minimum/maximum meterological data, with times
- 1440twr25m - Sixty Meter Tower: daily minimum/maximum met data, with times, at 25-m height
- 1440twr60m - Sixty Meter Tower: daily minimum/maximum met data, with times, at 60-m height
- 1twr10x - Sixty Meter Tower: temp, humidity & vapor pressure, 1-min avg
- 1twr21x - Sixty Meter Tower: temp, humidity & vapor pressure, 1-min avg
- 1twr25m - Sixty Meter Tower: 1-min average temp, humidity & vapor press. at 25-m height
- 1twr60m - Sixty Meter Tower: 1-min average temp, humidity & vapor press. at 60-m height
- 30twr10x - Sixty Meter Tower: temperature, humidity, & vapor pressure, 30-min avg
- 30twr21x - Sixty Meter Tower: temperature, humidity, & vapor pressure, 30-min avg
- 30twr25m - Sixty Meter Tower: temperature, humidity, & vapor pressure at 25-m, 30-min average
- 30twr60m - Sixty Meter Tower: temperature, humidity, & vapor pressure at 60-m, 30-min avg
Sites / Facilities
Note: Click the "" to expand/collapse the list.
- Southern Great Plains (SGP)
- Central Facility, Lamont, OK (C1)
Mentor(s)
David Cook
(630) 252-5840
drcook@anl.gov