CDC logoSafer Healthier People  CDC HomeCDC SearchCDC Health Topics A-Z
NIOSH - National Institute for Occupational Safety and Health

Document for Public Review and Comment:

The Potential Modification of the NIOSH Statement of Standard for a Chemical, Biological, Radiological, and Nuclear (CBRN) Full Facepiece Air-Purifying Respirator (APR)
NIOSH Docket 139

July 2008

The National Personal Protective Technology Laboratory (NPPTL) is currently seeking stakeholder input regarding a request from the Department of Defense (DoD). The request is for a proposed modification to the CBRN APR Statement of Standard to allow for mechanical connectors other than the specified single 40-mm thread connector. The DoD is seeking modification of the standard to allow DoD first responders to use a newly developed respirator, the Joint Service General Protective Mask (JSGPM), for respiratory protection on military installations in the United States, or when called upon to support civil authorities. The JSGPM uses a bayonet mounted, dual filter design instead of the single standard 40-mm screw mounted canister. DoD's request is to supplement the existing NIOSH standard with an alternate design for DoD application.

Background

Because of their experiences in responding to the terrorist events of 2001, emergency responders identified the need for the interoperability of canisters and facepieces as a respirator user issue that NIOSH needed to address.

During the evolution of the CBRN Statement of Standard, NIOSH identified a single mechanical connector design requirement to support interchangeability of CBRN certified canisters and masks. The user community strongly encouraged requiring interoperable capability at all three public meetings held that discussed the requirements for the CBRN APR, and interoperability was strongly recommended in the 2002 Rand Report entitled, "Protecting Emergency Responders Lessons Learned from Terrorist Attacks.'' Through a collaborative approach with multiple partnerships, applicable military and industrial technologies were integrated by NIOSH in the CBRN APR standard to provide the full range of protection needed by emergency responders.

Working with the partnerships from Federal government agencies, the private sector, and user groups, NIOSH expedited development and publication of new testing and certification standards for voluntary use by emergency responders in CBRN terrorist attacks. Information about the public meetings that discussed the conceptual requirements for the CBRN APR is available through this link: http://www.cdc.gov/niosh/npptl/standardsdev/cbrn/meetings.html. The NIOSH Statement of Standard and supporting concept papers for the CBRN APR are available through this link:  http://www.cdc.gov/niosh/npptl/standardsdev/cbrn/apr/.

Since the Standard was established in 2003, multiple models of CBRN APRs from multiple manufacturers have been certified to the Statement of Standard.

The DoD's request is to supplement the existing NIOSH standard with an alternate permissible design for DoD applications. DoD requirements for the JSGPM require availability of replacement filters in the mask carrier worn on the individual and field level logistic support for additional filters. Neither of these are requirements for commercial mask applications. For the DoD user, the advantages of the bayonet attachment on the JSGPM does not compromise the interoperability considerations for emergency responders outside of the DoD.

DoD Instruction 6055.1 indicates that in non-military unique workplaces where OSHA standards or other Federal safety standards apply but do not cover, or only partially cover, existing conditions, the DoD Components shall use appropriate national safety and occupational health consensus standards under Public Law 104-113. When there is no relevant OSHA or national consensus standard, the DoD Components may develop other protective measures to ensure the safety and health of DoD personnel. Also, the DoD Components may prescribe more stringent exposure limits or monitoring frequencies than those in the basic OSHA standards. Requesting NIOSH to include another mechanical connector design for DoD applications that may allow for NIOSH certification of the JSGPM meets this intent.

Input Sought from Stakeholders and Manufacturers:

Through this announcement, NIOSH/NPPTL is seeking input from stakeholders and manufacturers to determine the following:

  1. Opinions on the current design requirement for the single 40-mm thread canister mechanical connector.

  2. Rationale and data to maintain the current design requirement.

  3. Rationale and data to support adding an alternative design for DoD applications for canister mechanical connectors.

  4. Identification of alternative approaches to implement the alternative design concept for the canister mechanical connector.
  5. Other comments on the subject.

The DoD request to NIOSH for modification of the NIOSH Statement of Standard

Letter to Leslie Boord from the Department of the Army Joint Program and Executive Office for Chemical and Biological Defense, March 20, 2008 ReevesLtr3-25-08.pdf
(442KB; 1 page)
The free Adobe Acrobat Reader is needed to view these files. get acrobat reader

Public Comment Period

Comments will be accepted until 5:00 p.m. ET on October 16, 2008

To submit comments regarding this draft publication, please use one of these options:

  • Send NIOSH comments using this online form

  • Send comments by email.

  • Fax comments to the NIOSH Docket Office: 513-533-8285

  • Send by Mail to:
    NIOSH Mailstop: C-34
    Robert A. Taft Lab.
    4676 Columbia Parkway
    Cincinnati, Ohio 45226

Contact Person for Technical Information:

Jonathan V. Szalajda,
National Personal Protective Technology Laboratory (NPPTL), NIOSH, CDC

telephone (412) 386-6627

E-mail zfx1@cdc.gov

NIOSH Draft Documents for Public Review


NIOSH Home |  NIOSH Search  | Site Index  | Topic List | Contact Us