Certified List of Fume Suppressants for Facilities Performing Chrome Plating and Chromic Acid Anodizing Operations

Rule 1469, as amended May 2, 2003, requires the owner or operator of a chrome plating or chromic acid anodizing tank currently using a wetting agent fume suppressant to begin using a wetting-agent fume suppressant certified by AQMD.  This requirement becomes effective on May 2, 2004.  This is only one of several requirements facilities must comply with in Rule 1469.

Certification requires that the fume suppressant be able to reduce or suppress hexavalent chromium emissions at the surface of an electroplating or anodizing bath through the reduction of surface tension of the bath to a level at which an emission factor of 0.01 milligrams per ampere hour is achieved.

The following list of certified fume suppressants have all been tested and determined to meet an emission limitation of 0.01 milligrams of Cr+6/ampere-hour of applied current at the stated surface tension.

List of Certified Wetting-Agent Chemical Fume Suppressant Products, Companies, and Usage Restrictions

Company

Product

Usage Restrictions

Contact Name

Telephone

Atotech USA

Fumetrol 140

Shall be used at or below 40 dynes/cm

Gary Wannlund

(800)
443-9746

Atotech USA

Fumetrol 140 + Dis-Mist NP

Both products shall be used in combination at or below 45 dynes/cm.  A foam blanket of not less than one inch shall be maintained while plating, with foam blanket coverage of not less than 95% of the tank surface area.

Gary Wannlund

(800)
443-9746

Benchmark Products

Benchbrite CR-1800

Shall be used at or below 40 dynes/cm

Steve Erwin

(317)
875-0051

Enthone, Cookson Electronics

Zero Mist Liquid R

Shall be used at or below 32 dynes/cm

Brad Kerr

(800)
496-8326

Hunter Chemical LLC HCA-6.2 Shall be used at or below 32 dynes/cm Ben Brock (215)
782-8000
ext. 208
Hunter Chemical LLC HCA-4 Shall be used at or below 32 dynes/cm Ben Brock (215)
782-8000
ext. 208

MacDermid

Clepo Chrome Mist Control 74095

Shall be used at or below 40 dynes/cm

Ken Kraemer

(714)
850-1477

This list will be updated periodically when new products have been certified to meet the rule limit.  Contact Tom Liebel at (909) 396-2554 or tliebel@aqmd.gov for more information on product testing.

DISCLAIMER: All wetting-agent fume suppressant products included in this list are certified as able to meet an emission limitation of 0.01 milligrams of hexavalent chromium per ampere-hour of applied current, by reducing the surface tension of hexavalent chromium electroplating or chromic acid anodizing baths, provided they are used in sufficient quantity to reduce the surface tension of the plating or anodizing bath to the maximum level listed under “Usage Restrictions” in the table and while following manufacturers' usage directions.  SCAQMD Rule 1469(c)(3) requires the use of certified wetting-agent chemical fume suppressants as of May 2, 2004.  SCAQMD in no way endorses any of these products. This list is arranged alphabetically.  Source test results used to develop the maximum surface tensions listed under “Usage Restrictions” in this table are limited to certification of wetting-agent chemical fume suppressants only and should not be used for other purposes.