  • 1. ‫ﺑﺴﻤﻪ ﺗﻌﺎﻟﻲ‬‫ﻣﻌﺮﻓﻲ اﺳﺘﺎﻧﺪارد ﺟﻠﻮﮔﻴﺮي از اﻧﻔﺠﺎر )‪ (Explosion‬ﻳﺎ در ﺧﻮد ﺟﻤﻊ ﺷﺪن )‪ (Implosion‬ﺑﻮﻳﻠﺮﻫﺎي ﭼﻨﺪ‬‫ﻣﺸﻌﻠﻪ )ﻧﻴﺮوﮔﺎﻫﻲ( 9991:2058 ‪ NFPA‬ﺑﺎ ﺗﺄﻛﻴﺪ ﺑﺮ اﻫﻤﻴﺖ ﺷﻌﻠﻪﺑﻴﻦﻫﺎ وذﻛﺮ ﻧﻜﺎت ﻣﻬﻢ ﻓﻨﻲ ﭘﻴﺮاﻣﻮن آﻧﻬﺎ‬ ‫ﺗﺮﺟﻤﻪ و ﮔﺮدآوري: ﻣﻬﻨﺪس ﺣﻤﻴﺪ ﻛﺎﺗﺒﻲ-ﺷﺮﻛﺖ ﻣﺪﻳﺮﻳﺖ ﺗﻮﻟﻴﺪ ﺑﺮق ﺷﻬﻴﺪ رﺟﺎﻳﻲ‬ ‫ﻣﻘﺪﻣﻪ :‬‫ﻫﺪف از ﺗﺪوﻳﻦ و اراﺋﻪ اﺳﺘﺎﻧﺪارد 9991:2058 ‪ NFPA‬ﺗﻮﺻﻴﻪ ﺑﻪ رﻋﺎﻳﺖ ﻧﻜﺎت ﻓﻨﻲ در ﻃﺮاﺣﻲ، ﻧﺼﺐ و‬‫ﺑﻬﺮهﺑﺮداري ﺑﻪ ﻣﻨﻈﻮر ﺟﻠﻮﮔﻴﺮي از اﻧﻔﺠﺎر ﻳﺎ در ﺧﻮد ﺟﻤﻊ ﺷﺪن ﻛﻮره ﺑﻮﻳﻠﺮ ﻣﻲﺑﺎﺷﺪ و در اﻳﻦ ﺟﻬﺖ ﺣﺪاﻗﻠﻬﺎي‬‫اﻟﺰاﻣﺎت ﻃﺮاﺣﻲ، ﻧﺼﺐ وﺑﻬﺮﺑﺮداري و ﺗﻌﻤﻴﺮات ﺑﻮﻳﻠﺮ و ﺳﻴﺴﺘﻢﻫﺎي ﺳﻮﺧﺖ و ﻫﻮا و ﮔﺎز ﺧﺮوﺟﻲ ﻛﻪ ﺑﺎﻳﺪ رﻋﺎﻳﺖ‬‫ﺷﻮﻧﺪ در اﻳﻦ اﺳﺘﺎﻧﺪارد ﺑﻴﺎن ﺷﺪه اﺳﺖ در اﻳﻦ ﻣﻘﺎﻟﻪ ﺑﺪﻟﻴﻞ اﻫﻤﻴﺖ و ﺣﺴﺎﺳﻴﺖ ﺷﻌﻠﻪﺑﻴﻦﻫﺎ و ﻧﻘﺶ آﻧﻬﺎ در‬‫ﺣﻔﺎﻇﺖ ﺑﻮﻳﻠﺮ و ﺟﻠﻮﮔﻴﺮي از اﻧﻔﺠﺎر ﻛﻮره ﭘﺲ از ﻣﻌﺮﻓﻲ ﻛﻠﻲ اﺳﺘﺎﻧﺪارد ﻓﻮق راﺟﻊ ﺑﻪ ﻧﻜﺎت ﻓﻨﻲ ﻣﺮﺑﻮط ﺑﻪ اﻧﻮاع‬ ‫ﺷﻌﻠﻪﺑﻴﻦ ﺑﺤﺚ ﺷﺪه اﺳﺖ.‬ ‫اﻧﻔﺠﺎرات ﻛﻮره:‬‫ﻋﻠﻞ اﺳﺎﺳﻲ اﻧﻔﺠﺎرات ﻛﻮره ﺑﺮوز ﺟﺮﻗﻪ در زﻣﺎﻧﻲ ﻛﻪ ﻣﺨﻠﻮط ﻗﺎﺑﻞ اﻧﻔﺠﺎر ﺳﻮﺧﺖ و ﻫﻮا در ﻓﻀﺎي داﺧﻞ ﻛﻮره و‬‫ﻳﺎ داﻛﺘﻬﺎي ﻋﺒﻮر ﮔﺎز ﺧﺮوﺟﻲ ﻛﻮره ﺟﻤﻊ ﺷﺪه ﺑﺎﺷﺪ اﺳﺖ داﻣﻨﻪ و ﺷﺪت اﻧﻔﺠﺎر ﺑﺴﺘﮕﻲ ﺑﻪ ﻣﻴﺰان ﻧﺴﺒﺖ ﺑﻴﻦ‬‫ﺳﻮﺧﺖ و ﻫﻮاي وﺟﻮد در ﻣﺨﻠﻮط ﻗﺎﺑﻞ اﺣﺘﺮاق )در زﻣﺎن ﺑﺮوز ﺟﺮﻗﻪ( دارد. اﻧﻔﺠﺎر ﻛﻮره در اﺛﺮ ﻋﻤﻠﻜﺮد ﻧﺎﻣﻨﺎﺳﺐ‬‫ﭘﺮﺳﻨﻞ ﺑﻬﺮهﺑﺮداري و ﻳﺎ ﻃﺮاﺣﻲ ﻣﻨﺎﺳﺐ ﺗﺠﻬﻴﺰات ﻳﺎ ﺳﻴﺴﺘﻢ ﻛﻨﺘﺮل و ﻳﺎ اﺧﺘﻼل در ﻋﻤﻠﻜﺮد آﻧﻬﺎ ﻣﻤﻜﻦ اﺳﺖ‬ ‫رخ دﻫﺪ ﺑﻌﻀﻲ از ﻋﻮاﻣﻞ اﻧﻔﺠﺎر ﻛﻮره ﺑﺸﺮح ذﻳﻞ ﻣﻲﺑﺎﺷﺪ.‬
  • 2. ‫‪ (a‬ﺑﺮوز وﻗﻔﻪ در ﺗﺄﻣﻴﻦ ﺳﻮﺧﺖ و ﻫﻮاي ﻣﺸﻌﻠﻬﺎي اﺻﻠﻲ ﻳﺎ اﻧﺮژي اﻳﮕﻨﺎﻳﺘﻮر ﻣﻲﺗﻮاﻧﺪ ﺑﺎﻋﺚ ﻓﻘﺪان ﺷﻌﻠﻪ و‬ ‫ﺟﻤﻊ ﺷﺪن ﻣﺨﻠﻮط ﺳﻮﺧﺖ و ﻫﻮا و ﺟﺮﻗﻪ ﺑﺎ ﺗﺄﺧﻴﺮ ﺷﻮد.‬ ‫‪ (b‬ﻧﺸﺘﻲ ﺳﻮﺧﺖ و ﺟﻤﻊ ﺷﺪن آن در ﻛﻮره و ﺑﺮوز ﺟﺮﻗﻪ در زﻣﺎن ﻣﻨﺎﺳﺐ‬‫‪ (c‬ﻛﻮﺷﺶ ﻣﻜﺮر ﻧﺎﻣﻮﻓﻖ ﺟﻬﺖ روﺷﻦ ﻛﺮدن ﻳﻚ ﻣﺸﻌﻞ ﺑﺪون اﻧﺠﺎم ﻋﻤﻠﻴﺎت ﭘﺎﻛﺴﺎزي )‪(purging‬‬ ‫ﻣﻨﺎﺳﺐ ﻛﻪ ﻣﻨﺠﺮ ﺑﻪ ﺟﻤﻊ ﺷﺪن ﻣﺨﻠﻮط ﺳﻮﺧﺖ و ﻫﻮا ﮔﺮدد.‬‫‪ (d‬ﺟﻤﻊ ﺷﺪن ﻣﺨﻠﻮط ﺳﻮﺧﺖ و ﻫﻮا در اﺛﺮ ﻓﻘﺪان ﺷﻌﻠﻪ ﻳﺎ اﺣﺘﺮاق ﻧﺎﻗﺺ ﻳﻚ ﻳﺎ ﭼﻨﺪ ﻣﺸﻌﻞ در ﺣﺎﻟﻴﻜﻪ‬ ‫ﺳﺎﻳﺮ ﻣﺸﻌﻠﻪ ﺑﺼﻮرت ﻧﺮﻣﺎل روﺷﻦ ﻫﺴﺘﻨﺪ.‬‫‪ (e‬ﺟﻤﻊ ﺷﺪن ﻣﺨﻠﻮط ﻗﺎﺑﻞ اﻧﻔﺠﺎر ﺳﻮﺧﺖ و ﻫﻮا در ﻫﻨﮕﺎم ﺷﺎت دان ﻳﻚ ﻣﺸﻌﻞ و ﺑﺮوز ﺟﺮﻗﻪ در زﻣﺎن‬ ‫ﻛﻮﺷﺶ ﺑﺮاي اﺳﺘﺎرت ﻣﺠﺪد ﻣﺸﻌﻞ‬‫دﻻﻳﻠﻲ ﻛﻪ در ﺑﺎﻻ ذﻛﺮ ﺷﺪ ﺑﺼﻮرت ﻧﻤﻮﻧﻪ و اﺣﺘﻤﺎﻟﻲ ﻫﺴﺘﻨﺪ و ﻣﻤﻜﻦ اﺳﺖ اﻧﻔﺠﺎر ﻛﻮره ﺑﻪ دﻻﻳﻠﻲ ﻏﻴﺮ از اﻳﻦ‬ ‫ﻣﻮارد رخ دﻫﺪ.‬‫ﻋﻼوه ﺑﺮ اﻧﻔﺠﺎر ﻛﻮره ﻣﺸﻜﻞ دﻳﮕﺮي ﻛﻪ ﺑﺎﻋﺚ ﺗﺨﺮﻳﺐ ﻛﻮره ﻣﻲﮔﺮدد در ﺧﻮد ﺟﻤﻊ ﺷﺪن )‪(implosion‬‬‫اﺳﺖ ﻛﻪ ﺑﺪﻟﻴﻞ اﻫﻤﻴﺖ ﻣﻮﺿﻮع اﺷﺎرهاي ﻛﻮﺗﺎه ﺑﺪان ﻣﻲﮔﺮدد، در ﺷﺮاﻳﻂ زﻳﺮ اﻣﻜﺎن در ﺧﻮد ﺟﻤﻊ ﺷﺪن ﻛﻮره‬ ‫وﺟﻮد دارد.‬‫‪ (a‬اﺧﺘﻼل در ﻋﻤﻠﻜﺮد ﺗﺠﻬﻴﺰاﺗﻲ ﻛﻪ در ﺟﺮﻳﺎن ﮔﺎز ﺧﺮوﺟﻲ ﻛﻮره ﻧﻘﺶ دارﻧﺪ ﻣﺎﻧﻨﺪ ﺳﻴﺴﺘﻢ ﺗﻐﺬﻳﻪ ﻫﻮا و‬ ‫ﺧﺮوج ﮔﺎز )‪ FDF‬ﻳﺎ ‪(IDF‬‬ ‫‪ (b‬ﻛﺎﻫﺶ ﻧﺎﮔﻬﺎﻧﻲ ﻓﺸﺎر ﮔﺎز داﺧﻞ ﻛﻮره ﻧﺎﺷﻲ از ﻛﺎﻫﺶ ﺳﺮﻳﻊ ﺳﻮﺧﺖ ورودي ﻳﺎ ﺗﺮﻳﭗ ﺑﻮﻳﻠﺮ‬ ‫ﺗﺮﻛﻴﺐ دو ﺷﺮط )‪ (a‬و )‪ (b‬در ﺑﺴﻴﺎري از ﻣﻮارد ﺑﺎﻋﺚ در ﺧﻮد ﺟﻤﻊ ﺷﺪن ﻛﻮره ﻣﻲﮔﺮدد.‬‫ﻻزم ﺑﻪ ذﻛﺮ اﺳﺖ ﺳﻴﺴﺘﻢ اﺻﻠﻲ ﻛﻪ ﻣﺪﻳﺮﻳﺖ اﺣﺘﺮاق ﺑﻮﻳﻠﺮ را ﺑﻪ ﻋﻬﺪه دارد ﺳﻴﺴﺘﻢ ﻣﺪﻳﺮﻳﺖ ﻣﺸﻌﻠﻬﺎ )‪(BMS‬‬‫)‪ (Burner management system‬ﻣﻲﺑﺎﺷﺪ ﻛﻪ ﺑﻪ ﻣﻨﻈﻮر ﻛﺎرﻛﺮد اﻳﻤﻦ ﺑﻮﻳﻠﺮ در زﻣﺎن راه اﻧﺪازي و‬‫ﺑﻬﺮهﺑﺮداري ﻧﺮﻣﺎل و ﺧﺎرج ﺷﺪن و اﻓﺰاﻳﺶ، ﻛﺎﻫﺶ ﺑﺎر ﻃﺮاﺣﻲ ﺷﺪه اﺳﺖ ﻋﻼوه ﺑﺮ آن ﺳﻴﺴﺘﻢ ﺣﻔﺎﻇﺘﻬﺎي ﺑﻮﻳﻠﺮ‬‫ﻧﻘﺶ ﻣﻬﻤﻲ در ﺟﻠﻮﮔﻴﺮي از ﺑﺮوز ﺣﻮادث ﻓﻮق اﻟﺬﻛﺮ دارد و ﻣﺪارات ﻣﻨﻄﻘﻲ ﺑﺎﻳﺪ در ﺳﻴﺴﺘﻢ ‪ BMS‬و ﺣﻔﺎﻇﺖ‬‫ﺑﻮﻳﻠﺮ ﻃﻮري ﻃﺮاﺣﻲ ﮔﺮدﻧﺪ ﻛﻪ از ﺑﺮوز ﺣﻮادث ﻣﺨﺘﻠﻒ از ﺟﻤﻠﻪ اﻧﻔﺠﺎر ودر ﺧﻮد ﺟﻤﻊ ﺷﺪن ﻛﻮره ﺟﻠﻮﮔﻴﺮي‬‫ﻧﻤﺎﻳﻨﺪ ﻛﻪ در اﺳﺘﺎﻧﺪارد 9991:2058‪ NFPA‬ﺑﻄﻮر ﻣﺸﺮوح راﺟﻊ ﺑﻪ اﻟﺰاﻣﺎت اﺳﺎﺳﻲ ﺑﺮاي ﻋﻤﻠﻜﺮد ﺻﺤﻴﺢ‬
  • 3. ‫اﻳﻦ ﺳﻴﺴﺘﻢﻫﺎ ﻣﻄﻠﺐ اراﺋﻪ ﺷﺪه اﺳﺖ ﻳﻜﻲ از ﺗﺠﻬﻴﺰات ﻣﻬﻢ در ﺳﻴﺴﺘﻢ ﻣﺪﻳﺮﻳﺖ ﻣﺸﻌﻞ ﺷﻌﻠﻪ ﺑﻴﻦ ﻣﻲﺑﺎﺷﺪ. ﻛﻪ‬‫ﻧﻘﺶ ﻣﻬﻤﻲ در ﺣﻔﺎﻇﺖ ﻛﻮره و ﺟﻠﻮﮔﻴﺮي از اﻧﻔﺠﺎر دارد ﻛﻪ در اداﻣﻪ راﺟﻊ ﺑﻪ اﻧﻮاع آن و ﻧﻜﺎت ﻓﻨﻲ ﻣﺮﺗﺒﻂ ﺑﺤﺚ‬ ‫ﻣﻲﮔﺮدد.‬ ‫اﻟﺰاﻣﺎت اﺳﺎﺳﻲ ﺑﺮاي ﺳﻴﺴﺘﻢ ﻣﻮﻧﻴﺘﻮرﻳﻨﮓ و ﺗﺮﻳﭗ ﻣﺸﻌﻞ ﻋﺒﺎرﺗﻨﺪ از:‬ ‫‪ (a‬وﺿﻌﻴﺖ ﻧﺎﭘﺎﻳﺪاري اﺣﺘﺮاق ﺑﺎﻳﺪ ﺑﻪ اﻃﻼع اﭘﺮاﺗﻮر ﺑﺮﺳﺪ ﺗﺎ اﻗﺪام ﻣﻨﺎﺳﺐ ﺑﻌﻤﻞ آﻳﺪ.‬‫‪ (b‬ﺷﺎت دان اﺿﻄﺮاري ﻣﺸﻌﻞ ﺑﺎﻳﺪ در ﺷﺮاﻳﻂ ﺧﻄﺮﻧﺎﻛﻲ ﻛﻪ ﻣﻨﺠﺮ ﺑﻪ ﺟﻤﻊ ﺷﺪن ﺳﻮﺧﺖ ﺑﺪون اﺣﺘﺮاق‬ ‫ﻣﻲﮔﺮدد و ﺑﺼﻮرت اﺗﻮﻣﺎﺗﻴﻚ اﻧﺠﺎم ﮔﺮدد.‬ ‫اﻧﻮاع ﺷﻌﻠﻪ ﺑﻴﻦ :‬ ‫ﺳﻪ ﻧﻮع ﻛﻠﻲ ﺷﻌﻠﻪ ﺑﻴﻦ وﺟﻮد دارد:‬ ‫1- ﺷﻌﻠﻪ ﺑﻴﻦ ﻣﻴﻠﻪاي ﻳﻮﻧﻴﺰاﺳﻴﻮن ﻛﻪ در ﻣﺸﻌﻞ اﻳﮕﻨﺎﻳﺘﻮر اﺳﺘﻔﺎده ﻣﻲﮔﺮدد.‬‫2- ﺷﻌﻠﻪﺑﻴﻦﻫﺎي ﺗﺸﻌﺸﻌﻲ ﻛﻪ ﺗﺸﻌﺸﻌﺎت ﻧﺎﺣﻴﻪ ﺗﺤﺖ ﻧﻈﺎرت ﺧﻮد را ﻣﻲﺑﻴﻨﻨﺪ و ﺷﺪت ﻧﻮر ﺑﺎ ﻃﻴﻒ‬‫ﻓﺮﻛﺎﻧﺲ ﺧﺎص و ﻫﻤﭽﻨﻴﻦ ﻓﺮﻛﺎﻧﺲ ﻓﻠﻴﻜﺮ)‪ (flicker‬ﻣﻮﺟﻮد را اﻧﺪازهﮔﻴﺮي ﻣﻲﻛﻨﻨﺪ ﻣﺜﻞ‬ ‫ﺷﻌﻠﻪﺑﻴﻦﻫﺎي ﻣﺎوراﺑﻨﻔﺶ )‪ – (UV‬ﻣﺎدون ﻗﺮﻣﺰ )‪ (IR‬و ﺗﺮﻛﻴﺒﻲ)‪(UV/IR‬‬‫3- ﺷﻌﻠﻪﺑﻴﻦﻫﺎي ﺑﺼﺮي)‪ (Visual‬ﻛﻪ از دورﺑﻴﻦ )‪ (CCTV‬ﻣﺪار ﺑﺴﺘﻪ اﺳﺘﻔﺎده ﻣﻲﻛﻨﻨﺪ و ﺳﻴﮕﻨﺎل‬‫وﻳﺪﻳﻮﻳﻲ دورﺑﻴﻦ ﺑﻪ ﻳﻚ واﺣﺪ ﭘﺮدازﺷﮕﺮ ﺟﻬﺖ آﺷﻜﺎرﺳﺎزي ﺷﻌﻠﻪ ﻣﻨﺘﻘﻞ ﻣﻲﮔﺮدد آﺷﻜﺎر ﺳﺎز ﺳﻴﮕﻨﺎل‬ ‫ﻣﻮﺟﻮد را ﺗﺤﻠﻴﻞ ﻛﺮده و در ﺻﻮرت وﺟﻮد آﺛﺎر ﺷﻌﻠﻪ ﺧﺮوﺟﻲ ﻣﺮﺑﻮﻃﻪ را ﻓﻌﺎل ﻣﻲﻛﻨﺪ.‬ ‫ﺷﻌﻠﻪﺑﻴﻦﻫﺎي ﻣﻴﻠﻪاي ﻳﻮﻧﻴﺰاﺳﻴﻮن‬‫اﻳﻦ ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎ ﺑﺮاي ﻣﺸﻌﻞ ﭘﺎﻳﻠﻮت )اﻳﮕﻨﺎﻳﺘﻮر( اﺳﺘﻔﺎده ﻣﻲﺷﻮﻧﺪ اﻧﺮژي آزاد ﺷﺪه ﻧﺎﺷﻲ از اﺣﺘﺮاق ﺑﺎﻋﺚ‬‫ﻣﻲﺷﻮد ﻛﻪ اﻟﻜﺘﺮوﻧﻬﺎ از اﺗﻤﻬﺎ آزاد ﺷﺪه و ﻳﻮﻧﻬﺎي ﻣﺜﺒﺖ ﺗﺸﻜﻴﻞ ﮔﺮدد. اﻟﻜﺘﺮوﻧﻬﺎ ﺳﺒﻚ ﻫﺴﺘﻨﺪ و از ﺷﻌﻠﻪ‬‫ﻓﺎﺻﻠﻪ ﻣﻲ ﮔﻴﺮﻧﺪ وﻟﻲ ﻳﻮﻧﻬﺎي ﻣﺜﺒﺖ ﺳﻨﮕﻴﻨﺘﺮ ﻫﺴﺘﻨﺪ و در ﻧﺰدﻳﻜﻲ ﺷﻌﻠﻪ ﺑﺎﻗﻲ ﻣﻲﻣﺎﻧﻨﺪ)ﺷﻜﻞ 1(.ﺣﺎل اﮔﺮ‬‫دو اﻟﻜﺘﺮود ﻧﺰدﻳﻚ ﺷﻌﻠﻪ ﻗﺮار ﮔﻴﺮﻧﺪ و وﻟﺘﺎژ ‪ DC‬روي اﻟﻜﺘﺮودﻫﺎ ﻗﺮار ﮔﻴﺮد در ﻫﻨﮕﺎم وﺟﻮد ﺷﻌﻠﻪ در اﺛﺮ‬‫ﻳﻮﻧﻴﺰاﺳﻴﻮن ﻳﻮﻧﻬﺎ واﻟﻜﺘﺮوﻧﻬﺎ ﺟﺬب اﻟﻜﺘﺮودﻫﺎي ﺑﺎ ﺑﺎر ﻏﻴﺮ ﻫﻤﻨﺎم ﻣﻲﺷﻮﻧﺪ و ﺟﺮﻳﺎن اﻟﻜﺘﺮﻳﻜﻲ ﺑﻮﺟﻮد ﻣﻲآﻳﺪ‬
  • 4. ‫و ﺑﺎ ﺧﺎﻣﻮش ﺷﺪن ﺷﻌﻠﻪ ﺟﺮﻳﺎن اﻟﻜﺘﺮﻳﻜﻲ ﻧﻴﺰ ﻗﻄﻊ ﻣﻲﮔﺮدد و ﺑﺪﻳﻦ ﺗﺮﺗﻴﺐ ﻣﻲﺗﻮان وﺟﻮد ﻳﺎ ﻓﻘﺪان ﺷﻌﻠﻪ را‬‫اﻋﻼم ﻛﺮد. در اﻳﻦ روش ﻳﻚ ﭘﺘﺎﻧﺴﻴﻞ ﺧﻄﺮﻧﺎك وﺟﻮد دارد زﻳﺮا اﮔﺮ ﻳﻚ اﺗﺼﺎﻟﻲ ﻧﺎﺷﻲ از ذرات ﻣﻌﻠﻖ‬‫ﻣﻮﺟﻮد در ﻣﺤﻴﻂ اﻳﺠﺎد ﺷﻮد ﺟﺮﻳﺎن ﺷﻌﻠﻪ ﺑﻴﻦ ﺑﺮﻗﺮار ﺷﺪه و وﺟﻮد ﺷﻌﻠﻪ اﻋﻼم ﻣﻲﮔﺮدد در ﺣﺎﻟﻴﻜﻪ ﻣﻤﻜﻦ‬‫اﺳﺖ ﺷﻌﻠﻪ ﺧﺎﻣﻮش ﺷﺪه وﻟﻲ ﺟﺮﻳﺎن ﺳﻮﺧﺖ اداﻣﻪ ﭘﻴﺪا ﻛﻨﺪ و اﻳﻦ ﻣﻲﺗﻮاﻧﺪ ﻣﻨﺠﺮ ﺑﻪ اﻧﻔﺠﺎر ﻛﻮره ﮔﺮدد‬‫ﺑﻨﺎﺑﺮاﻳﻦ ﺑﺎ ﻃﺮاﺣﻲ ﺧﺎﺻﻲ ازﺷﻌﻠﻪ ﺑﻴﻦ ﻣﻴﻠﻪاي و اﺳﺘﻔﺎده از وﻟﺘﺎژ ‪ AC‬ﻣﻲﺗﻮان از ﺧﺎﺻﻴﺖ ﻳﻜﺴﻮﺳﺎزي‬‫ﺷﻌﻠﻪ اﺳﺘﻔﺎده ﻛﺮد و در اﻳﻦ ﺻﻮرت در ﻫﻨﮕﺎم وﺟﻮد ﺷﻌﻠﻪ ﺟﺮﻳﺎن اﻟﻜﺘﺮﻳﻜﻲ داراي ﻣﻮﻟﻔﻪ ‪ DC‬ﺧﻮاﻫﺪ‬‫ﺑﻮد)ﺷﻜﻞ 2( و در زﻣﺎﻧﻴﻜﻪ اﺗﺼﺎﻟﻲ ﺑﻴﻦ اﻟﻜﺘﺮودﻫﺎ اﻳﺠﺎد ﺷﻮد ﺑﺪﻟﻴﻞ ﻓﻘﺪان ﺷﻌﻠﻪ ﺟﺮﻳﺎن اﻟﻜﺘﺮﻳﻜﻲ ﻛﻪ اﻳﺠﺎد‬‫ﻣﻲﮔﺮدد ﻓﺎﻗﺪ ﻣﻮﻟﻔﻪ ‪ DC‬ﺧﻮاﻫﺪ ﺑﻮد ﺑﻨﺎﺑﺮاﻳﻦ ﻧﻘﻄﻪ ﺿﻌﻒ ﺟﺪي ﺳﻴﺴﺘﻢ ﺑﺎ وﻟﺘﺎژ ‪ DC‬ﺑﺮﻃﺮف ﺧﻮاﻫﺪ ﺷﺪ‬‫ﻻزم ﺑﻪ ذﻛﺮ اﺳﺖ ﺗﻮﺿﻴﺤﺎت ﻛﺎﻣﻠﺘﺮي راﺟﻊ ﺑﻪ ﻧﺤﻮه ﻋﻤﻠﻜﺮد ﺷﻌﻠﻪ ﺑﻴﻦ ﻳﻮﻧﻴﺰاﺳﻴﻮن در ﻣﺮاﺟﻊ ﻓﻨﻲ ﻣﻮرد‬‫اﺳﺖ.‬ ‫ﺷﺪه‬ ‫ذﻛﺮ‬ ‫ﻣﻘﺎﻟﻪ‬ ‫اﻳﻦ‬ ‫در‬ ‫اﺳﺘﻔﺎده‬ ‫ﺷﮑﻞ ١‬ ‫ﺷﮑﻞ ٢‬ ‫ﺷﻌﻠﻪﺑﻴﻦﻫﺎي ﺗﺸﻌﺸﻌﻲ :‬‫ﺑﻄﻮر ﻛﻠﻲ ﺷﻌﻠﻪ ﻳﻚ ﭘﺪﻳﺪه اﻟﻜﺘﺮوﻣﻐﻨﺎﻃﻴﺴﻲ ﻣﻲﺑﺎﺷﺪ زﻳﺮا ﭘﺲ از ﺗﺸﻜﻴﻞ آن ﻃﻴﻒ و ﺳﻴﻌﻲ از اﻣﻮاج‬‫اﻟﻜﺘﺮوﻣﻐﻨﺎﻃﻴﺴﻲ در ﻓﺮﻛﺎﻧﺴﻬﺎي ﻣﺨﺘﻠﻒ ﺗﻮﻟﻴﺪ و ﺳﺎﻃﻊ ﻣﻲﮔﺮدد ﻛﻪ ﺷﺎﻣﻞ اﻣﻮاج ﻣﺎدون ﻗﺮﻣﺰ ، ﻧﻮر ﻣﺮﺋﻲ و‬‫ﻣﺎوراﺑﻨﻔﺶ ﻣﻲﺑﺎﺷﺪ.)ﺷﻜﻞ3(ﺳﻮﺧﺘﻬﺎي ﻣﺨﺘﻠﻒ در ﺣﻴﻦ ﺳﻮﺧﺘﻦ ﺗﺸﻌﺸﻌﺎت ﻣﺨﺼﻮص ﺑﻪ ﺧﻮد را ﺗﻮﻟﻴﺪ‬‫ﻣﻲﻛﻨﻨﺪ و ﻧﺴﺒﺖ ﺑﻴﻦ ﺷﺪت اﻣﻮاج ﺑﺎ ﻓﺮﻛﺎﻧﺴﻬﺎي ﻣﺨﺘﻠﻒ در آﻧﻬﺎ ﻣﺘﻔﺎوت ﻣﻲﺑﺎﺷﺪ و ﻳﻜﻲ از ﭘﺎراﻣﺘﺮﻫﺎي‬‫اﻧﺘﺨﺎب ﺷﻌﻠﻪ ﺑﻴﻦ ﻣﻨﺎﺳﺐ ﺑﺮاي ﺣﻔﺎﻇﺖ ﺷﻌﻠﻪ ، ﻧﻮع ﺳﻮﺧﺖ ﻣﻮرد اﺳﺘﻔﺎده ﻣﻲﺑﺎﺷﺪ ﻣﺜﻼً در ﺳﻮﺧﺘﻬﺎي‬‫ﻛﺮﺑﻨﻲ ﺑﻴﺸﺘﺮ از ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﻣﺎدون ﻗﺮﻣﺰ ‪ IR‬و در ﺳﻮﺧﺘﻬﺎي ﻏﻴﺮ ﻛﺮﺑﻨﻲ ﻣﺜﻼً ﻫﻴﺪروژن از‬
  • 5. ‫ﺷﻌﻠﻪﺑﻴﻦﻫﺎي ﻣﺎوراء ﺑﻨﻔﺶ ‪ UV‬اﺳﺘﻔﺎده ﻣﻲﮔﺮدد در ﺿﻤﻦ ﭘﺪﻳﺪهﻫﺎي ﻏﻴﺮ از ﺷﻌﻠﻪ ﻧﻴﺰ ﻣﻲﺗﻮاﻧﻨﺪ ﻣﻨﺎﺑﻊ‬‫ﺗﺸﻌﺸﻊ اﻣﻮاج اﻟﻜﺘﺮوﻣﻐﻨﺎﻃﻴﺴﻲ ﺑﺎﺷﻨﺪ ﻣﺜﻞ ﺳﻄﻮح داغ داﺧﻞ ﻛﻮره و ﻧﻮر ﺧﻮرﺷﻴﺪ و ﺟﺮﻗﻪ و ﻗﻮس اﻟﻜﺘﺮﻳﻜﻲ‬‫ﺟﻮﺷﻜﺎري و رﻋﺪ و ﺑﺮق و اﺷﻌﻪ ‪ x‬و ﻏﻴﺮه ﻛﻪ ﻣﻲﺗﻮاﻧﻨﺪ ﻣﻨﺠﺮ ﺑﻪ ﺑﺮوز آﻻرﻣﻬﺎي ﻛﺎذب در ﺳﻴﺴﺘﻤﻬﺎي‬‫ﺷﻌﻠﻪ ﺑﻴﻦ ﮔﺮدﻧﺪ ﻛﻪ در ﺗﻜﻨﻮﻟﻮژﻳﻬﺎي ﺟﺪﻳﺪ ﺑﺮاي ﺣﺬف آﻧﻬﺎ ﺗﺪاﺑﻴﺮ ﻻزم اﻧﺪﻳﺸﻴﺪه ﺷﺪه اﺳﺖ ﻛﻪ در اداﻣﻪ‬ ‫ﺑﻄﻮر ﺧﻼﺻﻪ ﺑﻪ آﻧﻬﺎ اﺷﺎره ﻣﻲﮔﺮدد.‬‫ﺑﻄﻮر ﻛﻠﻲ ﺳﻪ ﻧﻮع ﺷﻌﻠﻪ ﺑﻴﻦ ﺗﺸﻌﺸﻌﻲ وﺟﻮد دارد. 1- ﻣﺎدون ﻗﺮﻣﺰ ‪ -2 IR‬ﻣﺎوراﺑﻨﻔﺶ ‪ -3 UV‬ﻧﻮع‬ ‫ﺗﺮﻛﻴﺒﻲ ‪UV/IR‬‬ ‫ﺷﮑﻞ ٣‬ ‫ﺷﻌﻠﻪ ﺑﻴﻦ ﻫﺎي ﻣﺎدون ﻗﺮﻣﺰ ‪: IR‬‬‫ﻣﺤﺪوده وﺳﻴﻌﻲ از ﻃﻴﻒ ﻓﺮﻛﺎﻧﺴﻲ اﻣﻮاج اﻟﻜﺘﺮوﻣﻐﻨﺎﻃﻴﺴﻲ ﺑﻴﻦ ﻃﻮل ﻣﻮج) ‪ 750 nm‬ﺗﺎ ‪ ( 1nm‬ﺷﺎﻣﻞ اﻣﻮاج‬‫057 ﺗﺎ ‪ ( 4400nm‬ﺑﺮاي آﺷﻜﺎر ﺳﺎزي ﺷﻌﻠﻪ ﻣﻮرد‬ ‫‪nm‬‬ ‫ﻣﺎدون ﻗﺮﻣﺰ ‪ IR‬ﻣﻲﺑﺎﺷﺪ و ﻣﺤﺪودهاي ﺑﻴﻦ )‬‫اﺳﺘﻔﺎده ﻗﺮار ﻣﻲﮔﻴﺮد ﻻزم ﺑﻪ ذﻛﺮ اﺳﺖ ﺳﻄﻮح داغ داﺧﻞ ﻛﻮره ﻧﻴﺰ اﻣﻮاج ﻣﺎدون ﻗﺮﻣﺰ در اﻳﻦ ﻣﺤﺪوده‬‫ﻓﺮﻛﺎﻧﺴﻲ را ﺳﺎﻃﻊ ﻣﻲﻧﻤﺎﻳﻨﺪ ﺑﻨﺎﺑﺮاﻳﻦ ﺑﺮاي ﺣﺬف اﻣﻮاج آﻧﻬﺎ و ﺟﻠﻮﮔﻴﺮي از ﺑﺮوز آﻻرم ﻛﺎذب در ﺷﻌﻠﻪ ﺑﻴﻦ‬‫ﻧﻴﺎز ﺑﻪ ﺗﺪاﺑﻴﺮ ﺧﺎﺻﻲ دارد. ﺑﻄﻮر ﻛﻠﻲ دوﻧﻮع ﺷﻌﻠﻪ ﺑﻴﻦ ﻣﺎدون ﻗﺮﻣﺰ دارﻳﻢ ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﺗﻚ ﻓﺮﻛﺎﻧﺴﻲ و‬ ‫ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﭼﻨﺪ ﻓﺮﻛﺎﻧﺴﻲ ﻛﻪ در ذﻳﻞ راﺟﻊ ﺑﻪ آﻧﻬﺎ ﺗﻮﺿﻴﺢ داده ﻣﻲﺷﻮد:‬
  • 6. ‫1- ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﺗﻚ ﻓﺮﻛﺎﻧﺲ ﻣﺎدون ﻗﺮﻣﺰ:‬‫ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﺗﻚ ﻓﺮﻛﺎﻧﺴﻲ داراي ﻳﻚ ﺳﻨﺴﻮر ﺣﺴﺎس ﺑﻪ اﻣﻮج ﻣﺎدون ﻗﺮﻣﺰ ﺑﺎ ﻃﻮل ﻣﻮج ‪4400 nm‬‬‫ﺗﺎ ‪ 4300mm‬ﻛﻪ ﻣﺮﺑﻮط ﺑﻪ ﺷﻌﻠﻪ ﻧﺎﺷﻲ از ﺳﻮﺧﺘﻦ ﺳﻮﺧﺘﻬﺎي ﻫﻴﺪرو ﻛﺮﺑﻦ ﻣﻲﺑﺎﺷﺪ اﺳﺖ ﺑﻨﺎﺑﺮاﻳﻦ ﻧﺴﺒﺖ‬‫ﺑﻪ ﺗﺸﻌﺸﻌﺎت ﻧﺎﺷﻲ از ﺳﻄﻮح داغ درون ﻛﻮره و ﻧﻮر ﺧﻮرﺷﻴﺪ و ﺳﺎﻳﺮ ﻣﻨﺎﺑﻊ ﺗﺸﻌﺸﻌﻲ ﺣﺴﺎس ﻧﻤﻲﺑﺎﺷﺪ در‬‫اﻧﻮاع ﺟﺪﻳﺪ ﺷﻌﻠﻪﺑﻴﻦﻫﺎي ﻣﺎدون ﻗﺮﻣﺰ داﻣﻨﻪ )‪ (Intensity‬و ﻓﺮﻛﺎﻧﺲ )‪ (Flicker‬اﻣﻮاج ﻣﺎدون ﻗﺮﻣﺰ‬‫اﻧﺪازهﮔﻴﺮي ﻣﻲﺷﻮد و ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻣﻴﺰان آﻧﻬﺎ وﺟﻮد ﻳﺎ ﻓﻘﺪان ﺷﻌﻠﻪ اﻋﻼم ﻣﻲﮔﺮدد ﻻزم ﺑﻪ ذﻛﺮ اﺳﺖ در اﺛﺮ‬‫واﻛﻨﺸﻬﺎي ﺷﻴﻤﻴﺎﻳﻲ ﺣﻴﻦ ﺳﻮﺧﺘﻦ ﻣﻮاد ﻫﻴﺪروﻛﺮﺑﻨﻲ اﻧﻔﺠﺎرات ﻛﻮﭼﻜﻲ رخ ﻣﻲدﻫﺪ ﻛﻪ ﻣﻨﺠﺮ ﺑﻪ اﻳﺠﺎد‬‫ﻓﺮﻛﺎﻧﺲ ﻓﻠﻴﻜﺮ ﻣﻲﺷﻮد )‪ (0~200Hz‬و اﻣﻮاج ﻣﺎدون ﻗﺮﻣﺰ ﻧﺎﺷﻲ از ﺳﻄﻮح داغ و ﺳﺎﻳﺮ ﻣﻨﺎﺑﻊ ﺗﺸﻌﺸﻌﻲ‬‫ﻓﺎﻗﺪ اﻳﻦ ﻓﺮﻛﺎﻧﺲ ﻓﻠﻴﻜﺮ ﻣﻲﺑﺎﺷﻨﺪ ﺑﻨﺎﺑﺮﻳﻦ ﺑﺮاي ﺗﺸﺨﻴﺺ ﺷﻌﻠﻪ از اﻳﻦ ﭘﺎراﻣﺘﺮ ﻫﻤﺮاه ﺑﺎ ﺷﺪت اﻣﻮاج ﻣﺎدون‬ ‫)ﺷﻜﻞ4و5(‬ ‫ﻣﻲﮔﺮدد.‬ ‫اﺳﺘﻔﺎده‬ ‫ﻗﺮﻣﺰ‬ ‫ﺷﮑﻞ ٥‬ ‫ﺷﮑﻞ ٤‬ ‫2- ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﻣﺎدون ﻗﺮﻣﺰ ﭼﻨﺪ ﻓﺮﻛﺎﻧﺲ :‬‫ﺳﻨﺴﻮرﻫﺎي ﻣﺎدون ﻗﺮﻣﺰ ﻧﺴﺒﺖ ﺑﻪ ﺗﺸﻌﺸﻌﺎت ﺑﺎ ﻃﻮل ﻣﻮج ﺑﻴﺸﺘﺮ از ‪ 1100nm‬ﺣﺴﺎﺳﻴﺖ دارﻧﺪ ﻛﻪ ﻣﻌﻤﻮﻻً ﻧﺎﺷﻲ‬‫از ﺣﺮارت ﺷﻌﻠﻪ ﻳﺎ ﺳﻄﻮح داغ داﺧﻞ ﻛﻮره ﻣﻲﺑﺎﺷﺪ. ﻣﺤﺪود ه ﻓﺮﻛﺎﻧﺴﻲ ‪ 4300~4400nm‬ﻣﺮﺑﻮط ﺑﻪ ﻓﺮﻛﺎﻧﺲ‬‫رزوﻧﺎﻧﺲ ﻣﻮﻟﻜﻮﻟﻬﺎي ﮔﺎز ﻛﺮﺑﻨﻴﻚ)2‪ (CO‬ﻣﻲﺑﺎﺷﺪ ﻛﻪ در ﻫﻨﮕﺎم ﺳﻮﺧﺘﻦ ﺳﻮﺧﺘﻬﺎي ﻫﻴﺪروﻛﺮﺑﻨﻲ ﺗﺸﻌﺸﻌﺎت ﺑﺎ‬‫اﻳﻦ ﻃﻮل ﻣﻮج ﺳﺎﻃﻊ ﻣﻲﮔﺮدد در ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﻣﺎدون ﻗﺮﻣﺰ ﭼﻨﺪ ﻓﺮﻛﺎﻧﺲ از دو ﻳﺎ ﺳﻪ ﺳﻨﺴﻮر اﺳﺘﻔﺎده ﻣﻲﺷﻮد‬‫ﻣﺜﻼً ﺳﻨﺴﻮر 1‪ S‬ﺗﺸﻌﺸﻌﺎت ﺑﺎ ﻃﻮل ﻣﻮج ‪ 1100nm ~4100nm‬را درﻳﺎﻓﺖ ﻣﻲ ﻛﻨﺪ وﺳﻨﺴﻮر 2‪ S‬ﺗﺸﻌﺸﻌﺎت‬‫ﻳﺎ ﻃﻮل ﻣﻮج ‪ 4300nm~4400nm‬را )ﻣﺮﺑﻮط ﺑﻪ 2‪ ( CO‬ﺟﺬب ﻣﻲ ﻛﻨﺪ )ﺷﻜﻞ 6(و ﻣﺪارات اﻟﻜﺘﺮوﻧﻴﻜﻲ‬
  • 7. ‫ﻧﺴﺒﺖ ﺑﻴﻦ اﻳﻦ داﻣﻨﻪ وﻟﺘ‪Ĥ‬ژ ﻧﺎﺷﻲ از ﺳﻨﺴﻮرﻫﺎي 1‪ S‬و 2‪ S‬را اﻧﺪازهﮔﻴﺮي ﻣﻲﻛﻨﻨﺪ. ﻣﻴﺰان اﻧﺮژي ﻧﺎﺷﻲ از ﺳﻨﺴﻮر‬‫2‪ (CO2)S‬ﻣﻲﺑﺎﻳﺴﺖ ﺑﺴﻴﺎر ﺑﻴﺸﺘﺮ از 1‪ S‬ﺑﺎﺷﺪ ﺗﺎ وﺟﻮد ﺷﻌﻠﻪ ﻧﺎﺷﻲ از ﺳﻮﺧﺘﻬﺎي ﻫﻴﺪروﻛﺮﺑﻨﻲ ﺗﺄﻳﻴﺪ ﺷﻮد ﭼﻮن‬‫در ﻏﻴﺮاﻳﻨﺼﻮرت ﺗﺸﻌﺸﻌﺎت ﻣﺎدون ﻗﺮﻣﺰ درﻳﺎﻓﺘﻲ ﻧﺎﺷﻲ از ﺳﻄﻮح داغ داﺧﻞ ﻛﻮره ﻣﻲﺑﺎﺷﺪ وﺷﻌﻠﻪ ﺧﺎﻣﻮش اﺳﺖ‬ ‫اﻟﺒﺘﻪ اﻳﻦ روش درﻛﻞ ﺣﺴﺎﺳﻴﺖ ﺷﻌﻠﻪ راﻛﻢ ﻣﻲﻛﻨﺪ و در ﻋﻮض دﻗﺖ آﻧﺮا اﻓﺰاﻳﺶ ﻣﻲدﻫﺪ. )ﺷﻜﻞ 6(‬ ‫ﺷﮑﻞ ٦‬ ‫ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﺗﺸﻌﺸﻌﻲ ﻣﺎورا ﺑﻨﻔﺶ )‪(UV‬‬‫ﺳﻨﺴﻮر ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﻣﺎورا ﺑﻨﻔﺶ ﻗﺎدر ﺑﻪ ﺟﺬب اﻧﺮژي ﺗﺸﻌﺸﻌﺎت در ﻣﺤﺪوده ﻓﺮﻛﺎﻧﺲ ﺑﺎ ﻃﻮل ﻣﻮج‬‫‪ 185nm ~ 260nm‬ﻣﻲﺑﺎﺷﺪ. ﻻزم ﺑﻪ ذﻛﺮ اﺳﺖ ﺗﺸﻌﺸﻌﺎت ‪ UV‬ﺧﻮرﺷﻴﺪ داراي ﻃﻮل ﻣﻮج ‪280nm‬‬‫اﺳﺖ و در ﺳﻨﺴﻮرﻫﺎي دﻗﻴﻖ اﻳﻦ ﻃﻮل ﻣﻮج ﺣﺬف ﻣﻲﺷﻮد ﺑﻨﺎﺑﺮاﻳﻦ آﻻرم ﻛﺎذب ﻧﺨﻮاﻫﻴﻢ داﺷﺖ وﻟﻲ در‬‫ﺳﻨﺴﻮرﻫﺎي ارزان ﻗﻴﻤﺖ ﺑﺎ ﭘﻬﻨﺎي ﻓﺮﻛﺎﻧﺲ ﻏﻴﺮ دﻗﻴﻖ اﻣﻜﺎن ﺟﺬف اﻧﺮژي ﻧﻮر ﺧﻮرﺷﻴﺪ و ﺑﺮوز ﺧﻄﺎ وﺟﻮد‬‫دارد. آﺷﻜﺎرﺳﺎزﻫﺎي ‪ UV‬ﺑﻪ اﻛﺜﺮ ﺷﻌﻠﻪﻫﺎي ﻧﺎﺷﻲ از ﺳﻮﺧﺘﻬﺎي ﻫﻴﺪروﻛﺮﺑﻨﻲ )ﻣﺨﺼﻮﺻﺎً ﮔﺎز( و ﻫﻴﺪروژن و‬‫ﻏﻴﺮه ﺣﺴﺎس ﻫﺴﺘﻨﺪ و ﺑﻄﻮر وﺳﻴﻊ ﻣﻮرد اﺳﺘﻔﺎده ﻗﺮار ﻣﻲﮔﻴﺮﻧﺪ وﻟﻲ در ﻣﻘﺎﺑﻞ ﻧﻮر ﻧﺎﺷﻲ از ﻋﻮاﻣﻞ ﺷﻌﻠﻪ ﻣﺜﻞ‬‫رﻋﺪ و ﺑﺮق و اﺷﻌﻪ ‪ X‬و ﺟﺮﻗﻪ و ﻗﻮس اﻟﻜﺘﺮﻳﻜﻲ ﺟﻮﺷﻜﺎري ﺣﺴﺎس ﻫﺴﺘﻨﺪ و در ﻣﻮرد ﻣﺸﻌﻠﻬﺎي ﻧﻴﺮوﮔﺎﻫﻲ‬ ‫در ﺳﻮﺧﺖ ﮔﺎز ﻣﻮرد اﺳﺘﻔﺎده ﻗﺮار ﻣﻲﮔﻴﺮﻧﺪ و ﺣﺴﺎﺳﻴﺖ ﻣﻨﺎﺳﺒﻲ دارﻧﺪ.‬ ‫ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﺗﺸﻌﺸﻌﻲ ﺗﺮﻛﻴﺒﻲ )‪(UV/IR‬‬‫اﻳﻦ ﻧﻮع ﺷﻌﻠﻪﺑﻴﻦﻫﺎي داراي ﻳﻚ ﺳﻨﺴﻮر ‪ IR‬و ﻳﻚ ﺳﻨﺴﻮر ‪ UV‬ﻣﻲﺑﺎﺷﻨﺪ ﻛﻪ ﺑﻄﻮر ﻣﺴﺘﻘﻞ ﻋﻤﻞ‬‫ﻣﻲﻛﻨﻨﺪ وﻟﻲ داراي ﻣﺪارات اﻟﻜﺘﺮوﻧﻴﻚ ﻣﺸﺘﺮك و ﻗﺎﺑﻠﻴﺖﻫﺎي ﻣﻨﺎﺳﺒﻲ ﺑﺮاي ﺣﺬف آﻻرﻣﻬﺎي ﻛﺎذب ﻫﺴﺘﻨﺪ‬‫و زﻣﺎن ﭘﺎﺳﺦدﻫﻲ ﺳﺮﻳﻌﻲ دارﻧﺪ وﻟﻲ در ﻣﻘﺎﺑﻞ آﻟﻮدﮔﻴﻬﺎي ﻧﺎﺷﻲ از روﻏﻦ و ﺑﺨﺎرات آب ﻧﻘﻄﻪ ﺿﻌﻒ دارﻧﺪ‬
  • 8. ‫اﻳﻦ ﺷﻌﻠﻪ ﺑﻴﻦ ﺑﺮاي ﺗﺸﻌﺸﻊ آﺗﺶ ﻧﺎﺷﻲ از ﺳﻮﺧﺘﻬﺎي ﻫﻴﺪروﻛﺮﺑﻨﻲ در ﺟﺎﺋﻴﻜﻪ ﺳﺎﻳﺮ ﻣﻨﺎﺑﻊ ﺗﺸﻌﺸﻌﻲ ﻣﺜﻞ‬ ‫ﺳﻄﻮح داغ و اﺷﻌﻪ ‪ X‬و ﻗﻮس اﻟﻜﺘﺮﻳﻜﻲ وﺟﻮد دارد ﻣﻨﺎﺳﺐ ﻣﻲﺑﺎﺷﺪ.‬ ‫ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﺑﺼﺮي) ‪( Visual‬‬‫ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﺑﺼﺮي از ﺟﺪﻳﺪﺗﺮﻳﻦ ﺗﻜﻨﻮﻟﻮژي در ﺗﺸﺨﻴﺺ ﺷﻌﻠﻪ اﺳﺘﻔﺎده ﻣﻲﻛﻨﻨﺪ در اﻳﻦ ﺷﻌﻠﻪ ﺑﻴﻨﻬﺎ از‬‫ﺗﻜﻨﻴﻜﻬﺎي ﭘﺮدازش ﺗﺼﻮﻳﺮي ﺑﺎ اﺳﺘﻔﺎده از دورﺑﻴﻦ ﻣﺪار ﺑﺴﺘﻪ ‪ CCTV‬و اﻟﮕﻮرﻳﺘﻤﻬﺎي ﭘﻴﺸﺮﻓﺘﻪ اﺳﺘﻔﺎده‬ ‫ﺷﺪه اﺳﺖ و ﺑﺮ اﺳﺎس اﻳﻦ اﻟﮕﻮرﻳﺘﻤﻬﺎ ﺗﺼﺎوﻳﺮ زﻧﺪه وﻳﺪﻳﻮﻳﻲ ﭘﺮدازش ﺷﺪه و ﻣﺸﺨﺼﺎت ﺷﻌﻠﻪ ﻣﻮﺟﻮد‬‫ﺗﻔﺴﻴﺮ ﻣﻲﮔﺮدد. ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻳﻨﻜﻪ اﻳﻦ ﺳﻴﺴﺘﻢ از ﺗﺼﺎوﻳﺮ ﻧﺎﺷﻲ از ﻧﻮر ﻣﺮﺋﻲ اﺳﺘﻔﺎده ﻣﻲﻛﻨﺪ ﺗﺸﻌﺸﻌﺎت‬‫ﻣﺎدون ﻗﺮﻣﺰ ﻧﺎﺷﻲ از ﺳﻄﻮح داغ داﺧﻞ ﻛﻮره ﺗﺄﺛﻴﺮي روي اﻳﻦ ﺳﻴﺴﺘﻢ ﻧﺪارد ﺿﻤﻨﺎً وﺟﻮد ذرات آب روي ﻟﻨﺰ‬‫دورﺑﻴﻦ ﻛﻪ ﻋﻤﻠﻜﺮد ﺷﻌﻠﻪﺑﻴﻦﻫﺎي ﻣﺎدون ﻗﺮﻣﺰ را ﻣﺨﺘﻞ ﻣﻲﻛﻨﺪ ﻧﻴﺰ ﺑﻲ ﺗﺄﺛﻴﺮ اﺳﺖ زﻳﺮا ﻧﻮر ﻣﻲﺗﻮاﻧﺪ از آب‬‫ﻋﺒﻮر ﻛﻨﺪ در ﺣﺎﻟﻴﻜﻪ اﻣﻮج ﻣﺎدون ﻗﺮﻣﺰ در آب ﺟﺬب ﻣﻲﮔﺮدد از ﻣﻌﺎﻳﺐ اﻳﻦ روش اﻳﻦ اﺳﺖ ﻛﻪ ﻓﻘﻂ ﺷﻌﻠﻪ‬‫را آﺷﻜﺎر ﻣﻲﻛﻨﺪ و ﺑﻪ آﺗﺸﻬﺎي ﺑﺪون ﺷﻌﻠﻪ ﻗﺎﺑﻞ ﺗﻮﺟﻪ ﺣﺴﺎﺳﻴﺘﻲ ﻧﺪارد ﺿﻤﻨﺎً ﺷﻌﻠﻪ ﻣﺸﻌﻠﻬﺎ ﺑﺼﻮرت وﻳﺪﻳﻮﻳﻲ‬‫ﻗﺎﺑﻞ ﻧﻤﺎﻳﺶ در ﻣﻮﻧﻴﺘﻮرﻫﺎي اﺗﺎق ﻓﺮﻣﺎن ﻣﻲﺑﺎﺷﺪ ﻛﻪ ﺑﻪ اﭘﺮاﺗﻮرﻫﺎ در ﻋﻤﻠﻜﺮد ﺻﺤﻴﺢ ﺑﻬﺮهﺑﺮداري از ﻧﻴﺮوﮔﺎه‬ ‫ﻛﻤﻚ ﻛﻨﺪ. )ﺷﻜﻞ 7(‬‫ﺷﮑﻞ٧‬
  • 9. ‫ﻃﻲ ﺟﺪول ﺷﻤﺎره ﻳﻚ ﻧﻘﺎط ﻓﻮت و ﺿﻌﻒ اﻧﻮاع ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎ ﺑﻴﺎن ﺷﺪه اﺳﺖ.‬ ‫ﻧﻮع ﺷﻌﻠﻪ ﺑﻴﻦ‬ ‫ﻧﻘﺎط ﻗﻮت‬ ‫ﻧﻘﺎط ﺿﻌﻒ‬ ‫آﻻرم ﻛﺎذب ﻧﺎﺷﻲ از اﺷﻌﻪ ‪ X‬ﺟﻮﺷﻜﺎري ﻣﻨﺎﺳﺐ – ﭼﻨﺪ ﻣﻨﻈﻮر ﺑﺮاي ﺷﻌﻠﻪ ﺳﻮﺧﺖ ‪UV‬‬ ‫ﮔﺎز ﻃﺒﻴﻌﻲ‬ ‫رﻋﺪ و ﺑﺮق‬ ‫-از ﻛﺎر اﻓﺘﺎدن در ﻣﻘﺎﺑﻞ ﻗﻄﺮات روﻏﻦ‬‫ﺣﺴﺎﺳﻴﺖ ﺑﻪ ﺗﺸﻌﺸﻊ ﺟﺴﻢ داغ درون ﻋﺪم ﺣﺴﺎﺳﻴﺖ ﺑﻪ اﺷﻌﻪ ‪ x‬ﺟﻮﺷﻜﺎري – ‪ IR‬ﺗﻚ ﻓﺮﻛﺎﻧﺲ‬ ‫رﻋﺪ و ﺑﺮق – ﺑﺮاي ﺷﻌﻠﻪ ﺳﻮﺧﺖ ﻣﺎﻳﻊ‬ ‫ﻛﻮره‬ ‫از ﻛﺎر اﻓﺘﺎدن در ﻣﻘﺎﺑﻞ ﻗﻄﺮات آب و‬ ‫وﺟﻮد ﻳﺦ‬ ‫ﻣﺼﻮﻧﻴﺖ ﺑﺎﻻ در ﻣﻘﺎﺑﻞ آﻻرﻣﻬﺎي ﻛﺎذب ‪IR‬‬ ‫ﻛﺎﻫﺶ زﻣﺎن ﭘﺎﺳﺦ دﻫﻲ‬ ‫-‬ ‫از ﻛﺎر اﻓﺘﺎدن در ﻣﻘﺎﺑﻞ ﻧﺎﺷﻲ از ﺟﺴﻢ داغ درون ﻛﻮره اﻓﺰاﻳﺶ ﭼﻨﺪ ﻓﺮﻛﺎﻧﺲ‬ ‫-‬ ‫ﺣﺴﺎﺳﻴﺖ‬ ‫ﻗﻄﺮات آب و وﺟﻮد ﻳﺦ‬ ‫ﻣﻨﺎﺳﺐ ﺑﺮاي ﺷﻌﻠﻪﻫﺎي ﻧﺎﺷﻲ از ﻣﺼﺪوﻣﻴﺖ ﺑﺎﻻ در ﻣﻘﺎﺑﻞ آﻻرﻣﻬﺎي ‪UV/IR‬‬ ‫ﻛﺎذب‬ ‫ﺳﻮﺧﺘﻬﺎي ﻫﻴﺪروﻛﺮﺑﻨﻲ‬ ‫از ﻛﺎر اﻓﺘﺎدن در ﻣﻘﺎﺑﻞ ﻗﻄﺮات آب‬ ‫روﻏﻦ و وﺟﻮد ﻳﺦ‬‫ﺑﺼﺮي )‪(visual‬‬ ‫ﻋﺪم ﭘﺎﺳﺦ ﺑﻪ آﺗﺸﻬﺎي ﻧﺎﺷﻲ - دﻳﺪن ﻣﺴﺘﻘﻴﻢ ﺷﻌﻠﻪ ﺗﻮﺳﻂ اﭘﺮاﺗﻮر‬ ‫-‬ ‫از ﺳﻮﺧﺘﻦ ﻫﻴﺪروژن و ﻣﺘﺎﻧﻮل -ﻋﺪم ﺣﺴﺎﺳﻴﺖ در ﻣﻘﺎﺑﻞ ﺗﺸﻌﺸﻊ ﺟﺴﻢ‬ ‫داغ درون ﻛﻮره‬ ‫ﺑﺪﻟﻴﻞ ﻧﺒﻮدن ﺷﻌﻠﻪ‬ ‫- ﻋﺪم ﺗﺄﺛﻴﺮ آب روي ﻟﻨﺰ آن‬ ‫ﭘﺎﺳﺦ دﻫﻲ ﻛﻨﺪ‬ ‫-‬ ‫ﺣﺴﺎﺳﻴﺖ ﻓﻘﻂ ﺑﻪ ﺷﻌﻠﻪ ﻫﺎي - ﻋﺪم ﺗﺄﺛﻴﺮ ﻣﻨﺎﺑﻊ ﺗﺸﻌﺸﻌﻲ ﻏﻴﺮ ﺷﻌﻠﻪ‬ ‫-‬ ‫روي ﻋﻤﻠﻜﺮد آن ﻣﺜﻞ ﺟﻮﺷﻜﺎري و ﻏﻴﺮه‬ ‫ﺑﺎ درﺧﺸﻨﺪﮔﻲ زﻳﺎد‬ ‫ﺟﺪول 1‬
  • 10. ‫اﻧﺘﺨﺎب ﺷﻌﻠﻪ ﺑﻴﻦ‬ ‫ﺑﺮاي اﻧﺘﺨﺎب ﺷﻌﻠﻪ ﺑﻴﻦ ﺑﺎﻳﺪ ﻣﻮارد ذﻳﻞ ﻣﺪ ﻧﻈﺮ ﻗﺮار ﮔﻴﺮد.‬ ‫1- ﻧﻮع ﺳﻮﺧﺖ ﻣﺼﺮﻓﻲ ﻣﺸﻌﻞ )ﻣﺎزوت، زﻏﺎل ﺳﻨﮓ، ﮔﺎزوﺋﻴﻞ، ﮔﺎز و ... (‬ ‫2- ﻧﺤﻮه آراﻳﺶ ﻧﺼﺐ ﻣﺸﻌﻠﻬﺎ در ﻛﻮره )ﻧﺼﺐ در دﻳﻮاره ﻳﺎ در ﮔﻮﺷﻪ(‬ ‫3- ﻛﻼس ﻣﺸﻌﻠﻬﺎي ﭘﺎﻳﻠﻮت )ﺟﺮﻗﻪ زن(‬ ‫ﻧﻮع ﺳﻮﺧﺖ :‬‫ﺗﻤﺎم ﺷﻌﻠﻪﻫﺎي ﻧﺎﺷﻲ از ﺳﻮﺧﺘﻦ ﻫﻴﺪروﻛﺮﺑﻦ اﺷﻌﻪ ﻣﺎوراﺑﻨﻔﺶ و ﻣﺎدون ﻗﺮﻣﺰ ﺗﻮﻟﻴﺪ ﻛﻨﻨﺪ ﺑﺮاي ﺳﻮﺧﺘﻬﺎي‬‫ﺳﺒﻚ ﻣﺜﻞ ﮔﺎزو ﮔﺎزوﺋﻴﻞ ﺷﻌﻠﻪ ﺑﻴﻦ ‪ UV‬ﻣﻨﺎﺳﺐ اﺳﺖ وﻟﻲ در ﺳﻮﺧﺘﻬﺎي ﺳﻨﮕﻴﻦ ﻣﺜﻞ ﻣﺎزوت ﺑﺪﻟﻴﻞ وﺟﻮد‬‫ذرات ﻫﻴﺪروﻛﺮﺑﻦ ﻧﺴﻮﺧﺘﻪ اﺷﻌﻪ ‪ UV‬ﺟﺬب ﻣﻲﺷﻮد وﻟﻲ اﺷﻌﻪ ‪ IR‬از ﺑﻴﻦ اﻳﻦ ذرات ﻋﺒﻮر ﻣﻲﻛﻨﺪ ﺑﻨﺎﺑﺮاﻳﻦ‬ ‫ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ‪ IR‬ﺑﺮاي ﺳﻮﺧﺖ ﻣﺎزوت ﻣﻨﺎﺳﺒﺘﺮ ﻫﺴﺘﻨﺪ‬ ‫آراﻳﺶ ﻣﺸﻌﻠﻬﺎ:‬ ‫ﺑﻄﻮر ﻛﻠﻲ دو ﻧﻮع آراﻳﺶ ﻧﺼﺐ ﻣﺸﻌﻞ در ﻛﻮره ﺑﻮﻳﻠﺮﻫﺎي ﻧﻴﺮوﮔﺎﻫﻲ وﺟﻮد دارد‬ ‫1- آراﻳﺶ ﻧﺼﺐ ﻣﺸﻌﻞ در دﻳﻮار‬ ‫2- آراﻳﺶ ﻧﺼﺐ ﻣﺸﻌﻞ در ﮔﻮﺷﻪ‬ ‫در ﻧﻮع ﻧﺼﺐ ﻣﺸﻌﻞ در دﻳﻮار ﺑﺮاي ﻫﺮ ﻣﺸﻌﻞ ﻳﻚ ﺷﻌﻠﻪ ﺑﻴﻦ ‪ IR‬و ﻳﻚ ﺷﻌﻠﻪ ﺑﻴﻦ ‪ UV‬ﻧﺼﺐ ﻣﻲﮔﺮدد.‬‫در ﻧﻮع ﻧﺼﺐ ﻣﺸﻌﻞ در ﮔﻮﺷﻪ ﻋﻼوه ﺑﺮ ﻧﺼﺐ ﺷﻌﻠﻪ ﺑﻴﻦ ﺑﺮاي ﻫﺮ ﻣﺸﻌﻞ ﺑﺎﻳﺪ ﺷﻌﻠﻪ ﺑﻴﻦﻫﺎي ﻣﺨﺼﻮص‬‫ﻧﻈﺎرت ﮔﻮي آﺗﺶ )‪ (Fireball‬ﻧﻴﺰ ﻧﺼﺐ ﮔﺮدد ﭼﻮن ﭘﺲ از ﺗﺸﻜﻴﻞ ﮔﻮي آﺗﺶ در داﺧﻞ ﻛﻮره ﻫﺮ ﮔﻮﻧﻪ‬ ‫ﻧﺎﭘﺎﻳﺎﻳﺪاري ﻧﺸﺎﻧﻪ ﺑﺮوز ﻣﺸﻜﻞ در ﺳﻴﺴﺘﻢ اﺣﺘﺮاق ﻣﻲﺑﺎﺷﺪ.‬ ‫3- ﻛﻼس ﻣﺸﻌﻠﻬﺎ:‬‫ﺑﻄﻮر ﻛﻠﻲ ﺳﻪ ﻛﻼس 1 و 2 و3 ﺑﺮاي ﻣﺸﻌﻠﻬﺎي ﺟﺮﻗﻪ زن در اﺳﺘﺎﻧﺪارد 2.58‪ NFPA‬ﺗﻌﺮﻳﻒ ﺷﺪه اﺳﺖ ﻛﻪ‬ ‫ﺑﻄﻮر ﻣﺸﺮوح در اﺳﺘﺎﻧﺪارد ﻓﻮق آورده ﺷﺪه اﺳﺖ.‬ ‫ﭘﺲ از اﻧﺘﺨﺎب ﻧﻮع ﺷﻌﻠﻪ ﺑﻴﻦ )‪ UV‬ﻳﺎ ‪ ( IR‬ﺑﺮاي ﺧﺮﻳﺪ و ﻧﺼﺐ ﺷﻌﻠﻪ ﺑﻴﻦ ﺑﺎﻳﺪ ﻣﻮارد ذﻳﻞ را در ﻧﻈﺮ ﺑﮕﻴﺮﻳﻢ.‬
  • 11. ‫1( ﺑﺎﻧﺪ ﻓﺮﻛﺎﻧﺴﻲ: ﺑﺎﻧﺪ ﻓﺮﻛﺎﻧﺴﻲ وﺳﻴﻊ ﺑﺎﻋﺚ اﻳﺠﺎد آﻻرﻣﻬﺎي ﻛﺎذب ﻣﻲﮔﺮدد‬ ‫2( رﻧﺞ : در ﭼﻪ رﻧﺞ ﻓﺮﻛﺎﻧﺲ ﺑﺎﻳﺪ ﺷﻌﻠﻪ آﺷﻜﺎر ﮔﺮدد.‬ ‫٣( زاوﻳﻪ دﻳﺪ: ﺷﻌﻠﻪ در ﭼﻪ ﻓﺎﺻﻠﻪاي و ﻳﺎ ﭼﻪ زاوﻳﻪاي ﺑﺎﻳﺪآﺷﻜﺎرﮔﺮدد.‬‫4( ﻣﺨﺮوط دﻳﺪ: ﻣﺨﺮوﻃﻲ ﻧﺎﻗﺺ ﺑﺎ زاوﻳﻪاي ﻓﻀﺎﻳﻲ ﺧﺎص ﻛﻪ ﺑﺎﻳﺪ ﻣﻮﻗﻊ ﻧﺼﺐ ﺷﻌﻠﻪ ﺑﻴﻦ در‬ ‫ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﮔﺮدد.‬ ‫5( ﻳﻜﭙﺎرﭼﮕﻲ ﻧﻮري: آﻳﺎ اﻣﻜﺎن ﺗﻨﻈﻴﻢ ﻟﻨﺰ وﺟﻮد دارد‬ ‫6( ﻗﺎﺑﻠﻴﺖ ﭘﺸﺘﻴﺒﺎﻧﻲ ﺗﻮﺳﻂ ﺳﺎزﻧﺪه‬‫7( ﻣﻨﻄﻘﻪ ﺧﻄﺮﻧﺎك )‪ : (HAZARD Zone‬ﻣﺤﻠﻲ ﻛﻪ ﺷﻌﻠﻪ ﺑﻴﻦ ﻧﺼﺐ ﻣﻲﮔﺮدد از ﻧﻈﺮ‬ ‫اﻣﻜﺎن اﻧﻔﺠﺎر در ﭼﻪ ﻧﺎﺣﻴﻪاي از ﻧﻮاﺣﻲ ﻗﺎﺑﻞ اﻧﻔﺠﺎر ﻗﺮار ﻣﻲﮔﻴﺮد‬ ‫8( ﻧﺸﺎن دﻫﻨﺪه: آﻳﺎ آﺷﻜﺎر ﺳﺎز داراي ﻧﺸﺎن دﻫﻨﺪه وﺿﻌﻴﺖ روي ﺑﺪﻧﻪ ﺧﻮد ﻣﻲﺑﺎﺷﺪ‬ ‫9( آﻳﺎ ﺑﺮوز ﻋﻴﺐ ﻣﻲﺗﻮاﻧﺪ ﻣﺎﻧﻊ ارﺳﺎل ﺳﻴﮕﻨﺎل آﻻرم ﺷﻮد‬ ‫01( آﻳﺎ ﺷﻌﻠﻪ ﺑﻴﻦ داراي ﻫﻴﺘﺮ ﺑﺮاي ﺟﻠﻮﮔﻴﺮي از ﻳﺦ زدﮔﻲ ﻣﻲﺑﺎﺷﺪ.‬‫11( آﻳﺎ ﺷﻌﻠﻪ ﺑﻴﻦ داراي ﻣﺪارات ﻣﺘﻤﺎﻳﺰ ﻛﻨﻨﺪه ﺗﺸﻌﺸﻌﺎت ﺟﺴﻢ داغ درون ﻛﻮره از ﺗﺸﻌﺸﻌﺎت‬ ‫ﻧﺎﺷﻲ از ﺷﻌﻠﻪ ﻣﻲﺑﺎﺷﺪ‬‫ﻻزم ﺑﻪ ذﻛﺮ اﺳﺖ اﺧﻴﺮاً ﭘﻴﺸﺮﻓﺘﻬﺎي ﺑﺴﻴﺎري در زﻣﻴﻨﻪ ﺗﻜﻨﻮﻟﻮژي ﺳﺎﺧﺖ ﺷﻌﻠﻪﺑﻴﻦﻫﺎ ﺣﺎﺻﻞ ﺷﺪﻫﺎﺳﺖ و‬‫ﻗﺎﺑﻠﻴﺖﻫﺎي آﻧﻬﺎ در ﻣﻘﺎﺑﻞ ﻣﺪﻟﻬﺎي ﻗﺪﻳﻤﻲ ﺑﺴﻴﺎر ﺑﺎﻻ رﻓﺘﻪ اﺳﺖ از ﺟﻤﻠﻪ ﻣﺼﻮﻧﻴﺖ در ﻣﻘﺎﺑﻞ ﻋﻴﺐ) ‪Fail Sale‬‬‫( و اﻣﻜﺎن ﺧﻮد آزﻣﺎﻳﻲ) ‪ .(Self Mointoring‬ﺑﺎ اﺳﺘﻔﺎده از دو ﻣﺪار اﻟﻜﺘﺮوﻧﻴﻚ ﻛﻪ ﻫﻤﺰﻣﺎن ﺳﻴﮕﻨﺎل‬ ‫ورودي ﺳﻨﺴﻮرﻫﺎ را درﻳﺎﻓﺖ ﻣﻲﻛﻨﻨﺪ و وﺿﻌﻴﺖ دﻳﮕﺮ را ﻫﺮ ﻟﺤﻈﻪ ﭼﻚ ﻣﻲﻧﻤﺎﻳﻨﺪ.‬‫ﺑﺪﻳﻦ ﺗﺮﺗﻴﺐ ﺳﻄﺢ ﻳﻜﭙﺎرﭼﮕﻲ اﻳﻤﻨﻲ ﺳﻴﺴﺘﻢ )‪ (Safety integrity level‬را ﺑﻬﺒﻮد دادهاﻧﺪ. ﻣﺒﺤﺚ ‪SIL‬‬‫در اﺳﺘﺎﻧﺪارد 80516 ‪ IEC‬ﻣﻄﺮح ﺷﺪه اﺳﺖ و ﺑﺮاي ﺷﻨﺎﺧﺖ آن اﺳﺘﻔﺎده از ﻣﺮاﺟﻊ ﻣﻌﺮﻓﻲ ﺷﺪه در اﻧﺘﻬﺎي‬ ‫ﻣﻘﺎﻟﻪ ﺗﻮﺻﻴﻪ ﻣﻲ ﮔﺮدد.‬
  • 12. ‫ و ﭘﻴﺶ ﻧﻮﻳﺲ اﺳﺘﺎﻧﺪارد ﺗﻮاﻧﻴﺮ ﺳﺎﻳﺮ ﻣﺮاﺟﻊ ﻣﻌﺮﻓﻲ‬NFPA 8502:1999 ‫ﻻزم ﺑﻪ ذﻛﺮ اﺳﺖ ﺑﺠﺰ اﺳﺘﺎﻧﺪارد‬‫ﺷﺪه در اﻳﻦ ﻣﻘﺎﻟﻪ ﺑﻄﻮر راﻳﮕﺎن ﻗﺎﺑﻞ داﻧﻠﻮد و ﻣﻄﺎﻟﻌﻪ ﻣﻲﺑﺎﺷﺪ . اﻣﻴﺪ اﺳﺖ ﻣﻄﺎﻟﺐ ﻣﻄﺮوﺣﻪ ﺑﺮاي ﻫﻤﻜﺎران‬ .‫ﮔﺮاﻣﻲ ﺳﻮدﻣﻨﺪ ﺑﺎﺷﺪ‬ : ‫ﻣﺮاﺟﻊ‬ 1- NFPA8205:1999 Furnace Explosions/Implosions In Multiple Burner Boilers 2- Flame & Gas Detection Handbook (WWW.ICEWEB.COM .AU) 3- Flame Detector Selection. Micropack Engineering LTD. 4- Flame Safeguarding using Ionization detection. Durag inc. 5- Handbook of Fire and explosion protection. Denis p. Nolan Publication:1996 6- Safety Instrumented System. Paul Gruhn. ISA .2006 (‫7- ﭘﻴﺶ ﻧﻮﻳﺴﻲ اﺳﺘﺎﻧﺪارد ﺣﻔﺎﻇﺖ ﺑﻮﻳﻠﺮﻫﺎي ﭼﻨﺪ ﻣﺸﻌﻠﻪ ﺗﻮاﻧﻴﺮ)آﻗﺎي رﺳﺘﻤﻲ- ﻗﺪس ﻧﻴﺮو‬